Search results

Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum

Help Support Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. S

    Sour/Acidity Adjustment on Flanders Red

    Would you add the full 1 lb like your recipe calls for? Also, if I'm trying to add from dregs, do you usually use a starter for sour dregs? I haven't harvested from a bottle before, most methods I read suggest creating a starter but the Wyeast website says Roeselare blend (which I used in the...
  2. S

    Sour/Acidity Adjustment on Flanders Red

    Not sure if this belongs in the Lambic/Wild forum but this one is much more active so starting here.. So I brewed the following Flanders Red recipe: https://www.homebrewtalk.com/forum/threads/rodenbach-clone.224122/#post-3463464 Brew day hit 1.060, was in primary for about 3 weeks and took it...
  3. S

    Getting a good seal in primary fermenter (no bubbles)

    Get a spray bottle and start spraying starsan anywhere the leak could possibly be - around the grommet, airlock, all round where the lid seals, etc. Do it during peak fermentation. You'll see bubbles somewhere.
  4. S

    Cellar temps with Cool Zone jacket

    Although I have seen this product discussed when I've done searches, I haven't seen my specific question answered: Does anyone have any experience using this cool zone jacket as a standalone cooling solution without the big enclosure? (i.e. just using the wrap instead of the wrap plus enclosure...
  5. S

    Amp meter issue

    I did end up figuring this out. After confirming that the wiring was correct about 100 times, I checked the connections going into the amp meter and one of the wires wasn't making proper contact. Quick fix.
  6. S

    Amp meter issue

    So I just finished my new control box build and everything looks pretty good so far except the meters. The amp meter will only display the '1 .' that you see in the image below. I checked the wiring and it seems to be good but I'll double check it tonight. The amp meter was purchased...
  7. Amp meter

    Amp meter

  8. S

    Garage ventilation

    I just moved into a new house and I'm looking to finalize my home brewery setup in the garage. My setup is all electric so there's no carbon monoxide worry, just moisture from evaporation. The setup will be at the back of my garage, all the way on the back wall from the garage door. I was...
  9. S

    Shunt (Amp Meter) questions

    So I'm building a new control panel and have a few questions about the shunt for the amp meter. I didn't have one in my last control panel so I'm pretty new to the functions of a shunt. (first two pics below are my shunt and the last is from electricbrewery.com - my reference for my build)...
  10. shunt2

    shunt2

  11. Shunt1

    Shunt1

  12. S

    5500W BK and 2000W HLT

    Thanks. I'll probably do that. Would I need a fuse on both hot wires or just one?
  13. S

    5500W BK and 2000W HLT

    Thanks Bobby, now I'm all up to speed. Would you advise against simply wiring up a 30A fuse to the power cord (outside the control panel) to account for this protection, or is that really not the way to go. Problem I have with the going the sub panel route is that I do not want 2...
  14. S

    5500W BK and 2000W HLT

    So could I install a 15 amp fuse to each hot wire to protect the control panel?
  15. S

    5500W BK and 2000W HLT

    So if I understand what a sticking relay is correctly - this would be if, for example, my contactor became corroded or something and started sparking. Then my panel could conceivably pull more than 30 amps and overheat?
  16. S

    5500W BK and 2000W HLT

    Can you explain the first sentence better? thanks for trying to explain but I'm not quite following everything just yet. Maybe it would be better if I asked a different question. Let's say I just bought one of the assembled 30A control panels from electric brewery...
  17. S

    5500W BK and 2000W HLT

    That's true, I could do that and I'll look into that. But I already have a HLT with a 2000w element installed so I won't be sinking any money into parts that will become obsolete in my future design.
  18. S

    5500W BK and 2000W HLT

    Yes, I'm saying that the 50a outlet will have 6 gauge running from the panel to the outlet. I'm just confused as to why I need the 30a breaker if the 50a is gfci protected. with the way I'm building my control panel, there's no way I'd be running more than 25 amps at a time during my brew.
  19. S

    5500W BK and 2000W HLT

    Thanks. My plan is to use the 10 gauge wire but keep the 50A source. There's no issue with that right? since I won't be pulling more than 22-24 amps at a time I think I'm good. As mentioned, the reason for the 50A breaker is because I have plans to buy an electric car in the next few years...
  20. S

    5500W BK and 2000W HLT

    So I'm looking to replace my control panel and looking to upgrade from 120V to 240V. Below I've modified one of P-J's diagrams to demonstrate the key change(s) that I'm trying to make. This is not my final diagram but I'm looking to confirm that my thinking on how to handle the heating...
Back
Top