  1. Cevan

    The Brew Stand Incredible Giveaway

    Hell ya... Count me in
  2. Cevan

    HomeBrewTalk 2014 Big Giveaway

    Count me in too !! Winner Winner Chicken Dinner
  3. Cevan

    Kegerator out of a Bull Semen Tank

    I agree with the last post... It's likely a high vacuum vessel. You don't want to be punching any holes in it. If it is there's probably a vacuum port somewhere on the outside of it.
  4. Cevan

    Reputable Source for SSRs?

    Opto22 ... Use em at work for 24/7 medical systems and I use them in my panel and and controllers. Never had any issues, still have never even had to replace one at work.
  5. Control Panel -Front

    Control Panel -Front

  6. Control Panel -Side

    Control Panel -Side

  7. 120v Control

    120v Control

  8. 120v Control 2

    120v Control 2

  9. My 20Gallon Setup

    My 20Gallon Setup

  10. Equipment

    Equipment

    My Setup
  11. Cevan

    Simple Brutus 10 HELP

    Amp = Watt \ Voltage ... So a 4500w element pulls around 19 amps. It would work and should boil 10 gallons, but I'm afraid to advise you that would be acceptable under electrical code. I wait for someone to chime in with a better knowledge of how much you can load a circuit safely.
  12. Cevan

    Simple Brutus 10 HELP

    1 5500w element pulls around 23amps, that's what I use in my 20 gallon kettles. You will definitely need at least a 30 amp service and you could run one element at a time with pumps, but you still won't be able run both elements at the same time.
  13. Cevan

    I want my power to plug into my kettle, not the other way around...

    You could just use male receptacle plug with a little pigtail , you don't have to have the mounted receptacle.
  14. Cevan

    Getting close to the finish line !!

    Finished up labels and added a few LEDs next to pump switches.
  15. Cevan

    Pid versus ssvr

    Lots of people use the PID to controll boil so its pretty much tried and true. The SSVR will offer much tighter control but in the end were just boiling wort right. I guess the PID would have the benefit of temp monitoring and alarms, not that it's really necessary in the boil kettle but convenient.
  16. Cevan

    Getting close to the finish line !!

    Thanks, the panel works great. Kettles are all wet tested and I auto tuned the HLT yesterday. I wired it a lil different so I could use it on 120v also...I made another 4 prong plug with the neutral jumped to the other leg of the 240. This way I can still use my old kettles for small batches and...
  17. Cevan

    Getting close to the finish line !!

    Ive been brewing for a few years off and on and figured it was about time to upgrade the setup, I had saved a little extra coil here and there for brew gear. I went with the Kal clone setup, his site and these boards have been supremely helpful in the process !! Heres a few pics of the...
  18. Cevan

    2 Position Switch To Control Voltage

    Just curious... how much you trying to boil 5 or 10 gallons
  19. Cevan

    2 Position Switch To Control Voltage

    The PID will change duty cycle of the SSR output... basically full on is 100% element on all the time, Manaul mopde at 85% will fire the element roughly every 5 seconds or so. Make sure the switches you got are properly rated ... a 5500w element at 240 pulls around 22amps. In my experience they...
  20. Cevan

    2 Position Switch To Control Voltage

    Why dont you just use the pid in manual mode to control the boil... you can set it to about 85% or so. No need to rewire anything. Do you have a control panel? or do you just plug power right in ?