  1. Brumateur

    Good cheap SSR heatsink

    This is a good heatsink, but you will need a fan if mounting it inside a box.
  2. Brumateur

    High Gravity BIAB Electric Brewing System

    I was out of country for half a year , so that's why I set 3 month waiting time (I had a chance to be back at home every 2 month) As about e-mails I always answered e-mails sent from eBay or brumatic.com. I haven't got any such e-mails from you. This site was banned at place were I was so I...
  3. Brumateur

    Rosemount RTD?

    Looks like it should work with no problem.
  4. Brumateur

    Rosemount RTD?

    Do you have any link to this probe spec?
  5. Brumateur

    PID Parameter help

    Bigger P make PID works more like a thermostat. Increased D helps compensate sudden changes in temperature.
  6. Brumateur

    PID Parameter help

    I'd try to set something like this P=20, I=1, D=2
  7. Brumateur

    Insulation as opposed to more wattage...

    in average 10 gallon uninsulated pot loosing around 300-600 Watt as heat loss (when not boiling).
  8. Brumateur

    PID protection

    It's not true. You can connect two 3 wire RTD probe to one PID using one DPDT switch with no problem.
  9. Brumateur

    A Single 5500 watt element large enough for 24.5 - 25 gallon boil ?

    Surface are definitely affect visual boiling intensity. But do not mix up boiling intensity and boiling off rate. If we are talking about the same heating power a bigger surface may have less visual boiling intensity but evaporation speed could be even bigger than in a narrow wessel.
  10. Brumateur

    Brumatic Controller

    See here - https://www.homebrewtalk.com/f170/pid-porn-hp612-vs-xmt612-vs-syl-2362-strip-show-476122/#post6791716
  11. Brumateur

    PID porn. HP612 vs XMT612 vs SYL-2362 strip show.

    Find one more Auber analog - N2006P Probably the closest one. On a left side is Auber on a right side is N2006P
  12. Brumateur

    PID porn. HP612 vs XMT612 vs SYL-2362 strip show.

    Auber (and its analogs) is more versatile, flexible and has more ways to be fine tuned. But in most cases you need only basic functionality. And MyPin is a good choice.
  13. Brumateur

    Brumatic Controller

  14. Brumateur

    Modifying still dragon controller

    Yes it can, but you need to use a relay output or additional circuitry.
  15. Brumateur

    Modifying still dragon controller

    Why not? You still can do it with DPDT switch.
  16. Brumateur

    Modifying still dragon controller

    It takes only1 minute to find a proper switch - http://www.ebay.com/itm/AC-660V-32A-16-Terminals-3-Positions-Rotary-Selector-Cam-Changeover-Switch-/190818503022
  17. Brumateur

    Wiring question

    Most 220V LED works OK on 120Volts. So one 220V LED wired in parallel with your heater should do what you want
  18. Brumateur

    Would STC-1000's work in place of the PID's?

    Stc comes with thermosensor, so actual difference will be around $15
  19. Brumateur

    Would STC-1000's work in place of the PID's?

    Yes, STC will work OK for HLT, but for RIMS you'll need a PID.
  20. Brumateur

    Syl-1512a

    Sure, you need a contactor and SSR only if you want to control a heating element.