Last night I tested a prototype BK built with a 7gal AL pot and 2000w HD element on a 20A dedicated circuit. I brought 6.25 gal to a boil in 35 min, and measured the evaporation rate after 60 min to be at 5.75 gal.
My next test will be to increase the gravity of water by mixing the appropriate amount of table sugar and repeating the same test. I will be measuring time to boil, evap rate and carmalization at the element.
I am very close to concluding that 5 gallon batches can be boiled with 120VAC.