JakeTheHopDog
Well-Known Member
Im brewing an APA (Color = 6) this weekend and need some help with my water profile. I got a report done by Ward Labs and using the EZ_water_adjustment spreadsheet by -TH-, I cant seem to get it adjusted to anything meaningful. Below are the reports findings. This is county water, run through a water softener (i.e. the high Sodium) and a refrigerator filter. Any help would be appreciated.
pH = 7.9
Total Dissolved Solids (TDS) Est = 206
Electrical Conductivity, mmho/cm = 0.34
Cations / Anions, me/L = 3.8 / 3.5
ppm
Sodium, Na = 81
Potassium, K = 1
Calcium, Ca = 4
Magnesium, Mg = < 1
Total Hardness, CaCO3 = 14
Nitrate, NO3-N = 0.7 (SAFE)
Sulfate, SO4-S = 3
Chloride, Cl = 9
Carbonate, CO3 = < 1
Bicarbonate, HCO3 = 183
Total Alkalinity, CaCO3 = 150
pH = 7.9
Total Dissolved Solids (TDS) Est = 206
Electrical Conductivity, mmho/cm = 0.34
Cations / Anions, me/L = 3.8 / 3.5
ppm
Sodium, Na = 81
Potassium, K = 1
Calcium, Ca = 4
Magnesium, Mg = < 1
Total Hardness, CaCO3 = 14
Nitrate, NO3-N = 0.7 (SAFE)
Sulfate, SO4-S = 3
Chloride, Cl = 9
Carbonate, CO3 = < 1
Bicarbonate, HCO3 = 183
Total Alkalinity, CaCO3 = 150