Search results

Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum

Help Support Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. swanwick

    Carbonation keg lid side issue

    FYI. I recently bought one of these carbonation keg lids because I figured it would get my beer to servable faster. All was good until I hooked up additonal kegs on the same manifold. Normally this is fine if you want the same pressure on all kegs. I have a second manifold with a regulator...
  2. swanwick

    BruControl Uniflex v2: Adding Devices

    ruh-roh. I was hoping to use all the digital outs. Pin 17 indicates that it uses port 0.
  3. swanwick

    BruControl: Multiple displays of the same device

    Rather than get two more temp probes right now, I am going to move two of my three temp probes around for different phases of the brew. My HERMS out inline temp probe will also be used for the chiller out inline probe during whirlpooling and chilling.....will def need to make sure I do not...
  4. swanwick

    BruControl Uniflex v2: Adding Devices

    @BrunDog I just changed my plumbing configuration to allow for cooling during whirlpool. Had to add two more moto-ball valves maxing my uniflex out with 11 digital outputs. When I went into software to add the last one on port 0, it is not appearing in my list of available ports. Is it...
  5. swanwick

    BruControl Uniflex v2: Adding Devices

    I put some metal bubble wrap around the MLT and the BK. Even if it is not helping much, I figured for $10 it would help to limit the heat in the garage in summer and may make a bigger difference in winter. Will probably pay for itself in saved electricity at some point. With the HERMS, HLT...
  6. swanwick

    BruControl Uniflex v2: Adding Devices

    Yessssss. That was the problem. #2 solved. I am fully back into script debug mode. Funny how you really need to think about simplification in order to test the script elements and then work back up to a more simulated dress rehearsal water brew once the scripts are mostly functional. My...
  7. swanwick

    BruControl: Brewery control & automation software

    Ah yes. Makes sense now that i see each vessel has its own pump so that it is always at the start of the loop it is using. Can also see that you are segmenting two different parts of the loop in order to be able to use two different pumps at the same time. Picture worth a thousand words...
  8. swanwick

    BruControl: Brewery control & automation software

    So, do you have three way valves at each connection point in the loop? Just opening the output and the input with a pump in-between would allow a loop to also flow back to the original output. Seems you would have to not only open an exit from the loop, but also block the continuing loop at...
  9. swanwick

    BruControl: Brewery control & automation software

    Interesting, so at flameout you start running the wort through the chiller and back to the whirlpool. Hadn't thought about that. So your steps are whirlpool/chill and then chill/transport-to-fermenter. My plan was Whirlpool and then chill/transport (hose water) and then chill in fermenter...
  10. swanwick

    BruControl: Brewery control & automation software

    Thank you to all who participated in the discussion of proportional valve use from late May, early June on this thread. My past rig was 3-tier so things you can do with pumps are all new to me. :) The PID settings stuff goes over my head, but may try to dig into that understanding down the...
  11. swanwick

    Re-Circulating pre-boil?

    Thanks guys. I am also going to pump wort into BK through the whirlpool inlet. My new system is electric and only 30amps which means that I can only have one of the two 5500watt elements on at a time. I am going to have to work out when is the right time to switch from using the PID to keep...
  12. swanwick

    Re-Circulating pre-boil?

    My past experience is with a 3 vessel tiered system. I am now in process building a 3 vessel single-tier HERMS system. So, I will newly have access to pumps which means I can whirlpool. I am wondering if there is any advantage to re-circulating the wort pre-boil? My hypothesis is that it...
  13. swanwick

    BruControl Uniflex v2: Adding Devices

    Sweet! @swimIan , you rock! Confirmed that works. Problem #3 solved. You have better creative troubleshooting skills than me, that is for sure. @BrunDog it is definitely confusing that the naming of the Input calls for "InputPortID" while the value passed to it is just "ID" given that...
  14. swanwick

    BruControl Uniflex v2: Adding Devices

    Yes, "string" leaves room for a number of different options. I have tried the device name: "HLT Temp" both in and out of quotes as well as the port ID: 200 both in and out of quotes. The device is a 1-wire analog input device that works fine in the scripting when accessing it as "HLT Temp"...
  15. swanwick

    BruControl Uniflex v2: Adding Devices

    I should also note that my Element Interlock is port 26 at true and port 27 at false. I have the "HLT Heat Duty" pointing to 26 and the "BK Heat Duty" pointing to 27. I believe that is the correct way to configure, but thought i should explicitly say it in case my assumption is incorrect. I...
  16. swanwick

    BruControl Uniflex v2: Adding Devices

    Thx @BrunDog and @swimIan #1 is now solved. The state = true vs. state = false is flipping it back and forth. I did not realize that Element Interlock was a digital output device....thought it was something unique that was separately coded by Pete. For #2 I have setup a test script. I...
  17. swanwick

    BruControl Uniflex v2: Adding Devices

    @swimIan, I appreciate the support. For #3, I am good with enabling and targeting. So where I am Enabling: understand from instructions, sample scripts, and your share Target: understand from instructions, sample scripts, and your share which element is going to fire in a "one PID, two...
  18. swanwick

    BruControl Uniflex v2: Adding Devices

    @BrunDog (or anyone else scripting with Uniflex), I am still struggling with three things related to the elements in my scripts I cannot see in the manual how (within a script) to flip the Element Interlock from #1 to #2. When I turn on a Heat Duty device coded to one of the ports that the...
  19. swanwick

    Questions for electric herms guys.....

    Thx @Control Freak I will have to "play" with it a bit to dial in. Do you know if water is a close enough approximation for testing as compared to soaking grain bed? Would prefer to have a decent sense of differential before first batch on newly built system. @Mad Mann I have probes in the...
  20. swanwick

    Questions for electric herms guys.....

    So what temp are you keeping your HLT? If your pump is on continuously, you can't go too far above desired mash temp and then when you want to raise the mash temp for step or mashout/sparge you can only do it at the speed that your heat source can raise the HLT and the MT. I have 5500w...
Back