  1. K

    My new brew system, a brutus 10 with some nice modifications

    I have the PID wired so that : 1 - hot wired directly from hot bus 2 - neutral from neutral bus 14 - going to valve plug-in 13 - from toggle switch 8, 9, 10 - for RTD probe And I have the toggle switch wire that way you explained except Im using 120 V, not 24V as I am not using a...
  2. K

    My new brew system, a brutus 10 with some nice modifications

    I found that part confusing. The settings I currently have are: inty - P10.0 outy - 4 HY - 3 atdu - 0 psb - 0 rd - 0 corf - 1
  3. K

    My new brew system, a brutus 10 with some nice modifications

    Hey Josh, have an auber PID question. I'm assuming you are using the on/off function. When my relays are connected (under the temperature setpoint) the Auber spits out the full 120V - as expected. But when the relays are not connected, the voltage only drops down to 115V. On/off mode to me...
  4. K

    My new brew system, a brutus 10 with some nice modifications

    Awesome! Thanks brother. In your build you used the transformer because your particular valves were 24v correct? Since I plan on aquiring 120v valves, you see any issues with the 120v going into PID terminal 13 from the toggle switch? They are the same PID's as you have, and if I...
  5. K

    My new brew system, a brutus 10 with some nice modifications

    Josh, thanks for your response and the wiring info, the diagram is great. I understand all but the toggle switch for the gas valve. Like I said, I'm a bit of an electrical wanker! My toggle switch has 6 posts. Any thoughs on which lead goes where? Normally I would learn by experimenting...