  1. S

    Dernord elements

    i have bought 2 of these for a 12KW setup. very impressive elements!! but also very long! 48cm (almost 19inch) i also added the stainless steel caps
  2. S

    PID controller - timer wiring

    please use a different SSR these foteks use very under rated components. A 40A fotek uses a 25A triac, a 25A fotek uses a 12A triac. compared to other SSR's they are not completely filled with resin. there are other cheap better SSR's
  3. S

    Building a three phased controller

    the unit has 3 elements @ 230v with a combined neutral the rest is the same as a single phase controller. L1 -> A1/A2 -> Element L1 L2 -> B1/B2 -> Element L2 L3 -> C1/C2 -> Element L3 this is how you connect the 5 wires to your element and use CEE 5-pole powerplugs and sockets rated at...
  4. S

    How to test a temperature probe?

    you can check all your connections like this: disconnect your temperatureprobe from your PID and put your multimeter to Ohms. measure the resistance between the 2 wires a PT100 temperature probe should have 100 ohms at 0°C and around 108 ohms at room temperature. So if you measure that the probe...
  5. S

    What PID for HLT in HERMS?

    I'm not a guru, but I like to play with them :D i have a 2404, 2604, 2704, a couple of 3200 series and a 3504 with ethernet connection. I use DC OP 4-20mA to control a SSVR (basicly a giant light dimmer) to control a potstill. 3 of them to control 3 phase 400v 9kw heating element. I would like...
  6. S

    What PID for HLT in HERMS?

    I know there is a guy in Belgium who sells those modules very cheap. You might send him a message what shipment costs would become to the US and if he doesn't mind to ship to the US. I bought some other eurotherm stuff from the guy...
  7. S

    What PID for HLT in HERMS?

    what output modules are currently in your Eurotherm? Analog Output (DC OP), Relay Output or Logic Output? which (fancy) controllers do you have?