  1. volsherdeers

    Help tuning SYL 2362

    I'm assuming your temp prob is located in the outlet plumbing ?
  2. volsherdeers

    Help with Auber 2352 PIDs

    4.10 Input offset “Pb” Pb is used to set an input offset to compensate the error produced by the sensor or input signal itself. For example, if the controller displays 5oC when probe is in ice/water mixture, setting Pb = -5, will make the controller display 0o C.
  3. volsherdeers

    Help with Auber 2352 PIDs

    Just thought it would be a simpler alternative solution instead of adjusting the other 3 default perimeters.
  4. volsherdeers

    Help with Auber 2352 PIDs

    You may want to consider just using the "PB" Input offset feature
  5. volsherdeers

    Help with Auber 2352 PIDs

    You may want to consider just using the "PB" Input offset feature
  6. volsherdeers

    Help with Auber 2352 PIDs

    You may want to consider just using the "PB" Input offset feature
  7. volsherdeers

    Help with Auber 2352 PIDs

    Owners Manual: Page 3
  8. volsherdeers

    Auber SYL-2362 Alarms

    You could set alarm2 for your sparge temp and eliminate at least one step
  9. volsherdeers

    Help with Auber 2352 PIDs

    P=500 I=1000 D=120 T=2 for SSR Now look @ ALL defaults and reconfigure. After all the settings are back to default, then set these perimeters! Sn Pb Filt A-M Then A-T
  10. volsherdeers

    Help with Auber 2352 PIDs

    What are your P, I, & D settings ? Have you reviewed ALL settings and compared them to factory ?
  11. volsherdeers

    Help with Auber 2352 PIDs

    Is this unit New ? Any chance the "Lock Code" has been implemented ? thus not allowing some perimeters to be changed! Check all settings for default values.
  12. volsherdeers

    Help with Auber 2352 PIDs

    Sounds like it might sill be in A-T learning mode. Did you let it finish ? Are you getting any temp reading in other modes ?
  13. volsherdeers

    Help with Auber 2352 PIDs

    After A-T completes it process hold set bottom for 3 sec to enter the settings mode. Cycle to the A-M setting and change to 0 then wait till it exits. If the A-M light is not on press the set button. Press up/down buttons till the lower green numbers reads "M 100" if the "M" is not displayed...
  14. volsherdeers

    Help with Auber 2352 PIDs

    Is the AM light flashing ?
  15. volsherdeers

    Help with Auber 2352 PIDs

    The AM light will be on with "M 100" in the lower right display.
  16. volsherdeers

    Help with Auber 2352 PIDs

    The AM light will be on with "M 100" in the lower right display.
  17. volsherdeers

    Help with Auber 2352 PIDs

    The AM light will be on with "M 100" in the lower field
  18. volsherdeers

    Help with Auber 2352 PIDs

    Per Kal's Inst. A-M: This controls whether automatic or manual (or both) PID control modes are allowed. Automatic mode controls the heating element based on temperature while manual mode uses duty cycle . The default value of 2 disables manual mode completely and is fine for the Hot Liquor Tank...
  19. volsherdeers

    Help with Auber 2352 PIDs

    Doesn't really look like an "M"