  1. RiverCityBrewer

    BruControl: Brewery control & automation software

    I know the feature request list is probably getting deep, but I had a thought that might be of interest for a number of users. In industry, we use process cameras all over, and in our plant system we can overlay and control IP camera streams direct from the HMI. I thought it would be a nice...
  2. RiverCityBrewer

    BruControl: Brewery control & automation software

    Ah ok, the 6004 is what I have as well. Its a good flow meter, you'll like it.
  3. RiverCityBrewer

    BruControl: Brewery control & automation software

    No need for an external transmitter with the IFM series, they are built in. Looking at the manual for the SM4000, it will output 21.5mA at 100C. I would figure on maxing out the 5v pin with 22mA, so that would be a 227ohm resistor. Also, it looks like the analog outputs can be switched from...
  4. RiverCityBrewer

    BruControl: Brewery control & automation software

    Easiest way is 160-165 ohm for 3.3v logic and 245-450 ohm for 5v logic. Its important to make sure your transmitters are set to 0ma for faults instead of 22ma for faults as it can overvolt your board if you are at the upper end of the resistance range...
  5. RiverCityBrewer

    BruControl: Brewery control & automation software

    I put it on a test bench board and wired up an analog. Working great! I'll let it run for a few days and report back.
  6. RiverCityBrewer

    BruControl: Brewery control & automation software

    Thanks, I just emailed you. I've also noticed that the ADC on the ESP32 wasn't exactly what you would call linear, and I agree with you that a lookup table is the best option. Looking forward to trying it out.
  7. RiverCityBrewer

    BruControl: Brewery control & automation software

    Perhaps I missed it somewhere, but does the functionality exist to enable the 12-bit ADC on the ESP32?
  8. RiverCityBrewer

    BruControl: Brewery control & automation software

    Oops, yes you are completely right, totally blanked on just bridging the trigger input.
  9. RiverCityBrewer

    BruControl: Brewery control & automation software

    I think on a UM-1 you would need 2 pairs of I/O configured in double throw mode (dual throw port config) to use a CR05 valve natively. I would use CR03 valves with the SPST relays native on the UM-1, or use a SPST to trigger a supplemental board of DPDT relays to cycle your CR05 valves. Edit...
  10. RiverCityBrewer

    BruControl: Brewery control & automation software

    True, I'm not running 50+ amps through the neutral, but I'd rather size for worst case scenario, especially since the cost difference is in single dollars.
  11. RiverCityBrewer

    BruControl: Brewery control & automation software

    Your terminal blocks should be sized appropriately to your loads. I use Phoenix UT10 which can handle > 50 amps. https://www.phoenixcontact.com/online/portal/us?uri=pxc-oc-itemdetail:pid=3044160&library=usen&tab=1
  12. RiverCityBrewer

    BruControl: Brewery control & automation software

    No, because the load in that instance is a contactor, not a heating element, and the wiring is protected by a 1amp fuse.
  13. RiverCityBrewer

    BruControl: Brewery control & automation software

    Yep, that's fine and all, but when you say you are still getting ~5v at 127 pwm, that makes me think your pot screws are set wrong. With pwm at 255, turn down the pot until you see some downward movement on your meter. Then try setting 127 and see if you get ~2.5v
  14. RiverCityBrewer

    BruControl: Brewery control & automation software

    Hmm, that was an easy first thought. Have you adjusted the pot screws for your high and low ranges?
  15. RiverCityBrewer

    BruControl: Brewery control & automation software

    You don't happen to have a linear multiplier of 2.55 enabled on your pwm elements, do you?
  16. RiverCityBrewer

    Controller Troubleshooting

    I assume your 80v measurement is between the hot and neutral, what does it read between hot and ground? I also don't understand the connections to your pushbutton switches, why are there two hot legs running to them? Maybe a link to the pushbutton switch would give me a better understanding of...
  17. RiverCityBrewer

    BruControl: Brewery control & automation software

    I'm not familiar with Endress+Hauser, but many sensors with *newer* busses have a fallback to modbus. You might poke around the manual for your specific model and see if that is an option. If you can output modbus, I can help you get it into node-red and thus BC (if you have the correct license).
  18. RiverCityBrewer

    BruControl: Brewery control & automation software

    I did it via modbus and node red....