• Please visit and share your knowledge at our sister communities:
  • If you have not, please join our official Homebrewing Facebook Group!

    Homebrewing Facebook Group

Search results

Homebrew Talk

Help Support Homebrew Talk:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. S

    BruControl: Brewery control & automation software

    How do I (or can I) use the same interface in two different configurations? When I tried it, it connected on one of them, but not the other.
  2. S

    BruControl: Brewery control & automation software

    I need to put a hole in my mashtun to install one of brucontrols volume sensors. I have seen some posts regarding side mount vs bottom mount. One thing I was wondering about is under the false bottom or above it? I could imagine that this could be very useful to predicting a stuck mash if...
  3. S

    BruControl: Brewery control & automation software

    Sounds like you are setting up a full multi-media experience with Brucontrol and ESPN3 :)
  4. S

    BruControl: Brewery control & automation software

    I found the issue. The was a pin inside the sensor that was touching the housing causing a short.
  5. S

    BruControl: Brewery control & automation software

    That reads around 40F with a 100ohm resistor.
  6. S

    BruControl: Brewery control & automation software

    RTD issue: I have 7 out of 8 RTD's working. The other one is reading -413. 2 of the 8 are inline sensors and one of these is not working. I have it isolated to the sensor itself because there are disconnects at the sensor and if I swap these 2, the output swaps in BruControl (sensor 1 goes...
  7. S

    BruControl: Brewery control & automation software

    Should have said Vs, not Cs. Per the unishield manual, I have the power switch set to VR-->Vin and set the DDPS to 8V (manual states 7-9V. I have been running this for a couple of weeks with no issues.
  8. S

    BruControl: Brewery control & automation software

    Quick update. I reinstalled the interface firmware. That was successful, but it still will not respond in termite. I am not sure what to do next. Any ideas?
  9. S

    BruControl: Brewery control & automation software

    I had a bit of a setback and need some help troubleshooting. One of my rtd's was not working, so I was troubleshooting by swapping 2 of the cs wires. Power was off. This was fine, so I powered off again, put them back where they started and then my interface would not connect. I removed the wifi...
  10. S

    BruControl: Brewery control & automation software

    After scratching my head a bit this week trying to calibrate sensors, I found out the adc on the grand central is 12 bit, not 10 bit as described on Adafruit. What's up with that? Not that I am complaining, just a bit surprised.
  11. S

    Resistors for volume sensos

    Yes it is ok to run multiple devices off a single power supply, you just need to check the power rating on you power supply. you should be able to get current or power useage from a device data sheet. In general, sensors use very little power, motors and heaters use more. Always on does not...
  12. S

    Resistors for volume sensos

    Resistor size does not matter, it should be very low power. You may want 1% accuracy resistors. Power is 12-30V, so your 24V ps will work well. Wiring is red to 24v, yellow to DC ground and blue to your voltage divider and then analog pin.
  13. S

    BruControl: Brewery control & automation software

    @oakbarn , thanks for taking the time to put this down. It is very helpful.
  14. S

    BruControl: Brewery control & automation software

    Does anyone have a brewday flow chart for how you have set up brucontrol? I don't want all the script detail because I think the differences between systems will make it not so valuable. I have seen some nice setups with timers for each step and would like to see how it was done.
  15. S

    BruControl: Brewery control & automation software

    How about on the grand central?
  16. S

    BruControl: Brewery control & automation software

    Do I need to wire the aref pin for Brucontrol? Your schematic shows tying it to 5v on a mega. Typically I would not hook up aref unless I wanted a different reference voltage than the interface internal reference.
  17. S

    BruControl: Brewery control & automation software

    I get a different answer. 1.8k an 3.3k give 3.24V at 1mA. Am I doing something wrong?
  18. S

    BruControl: Brewery control & automation software

    Reading through @crane thread, I am assuming this was not implemented in Brucontrol yet @BrunDog ?
  19. S

    3 way liquid splitter?

    If you set it up as described with a manifold and 3 same length tube, theoretically you will create a water level and end up with equal amounts in each keg. I do this when splitting mash runnings into two BKs. In practice it can be difficult to purge all the air out of the lines and air will...
  20. S

    BruControl: Brewery control & automation software

    @oakbarn This looks great, I would like a copy. I sent you a PM with my email address.
Back