  1. C

    NEW StrangeBrew Elsinore Thread

    Correct suggestion. When finished I will open a thread. So do not overload this, and can contribute experiences. Check the mail, just send translation.
  2. C

    NEW StrangeBrew Elsinore Thread

    Hello. I used a liter of water to learn and PID ready. Yesterday I made more than 20 tests, and could not be emptied twenty or thirty liters per two or three tests. This is the first step. Once I mastered the process of tuning, I will now do it in real conditions (30 liters). I will use...
  3. C

    NEW StrangeBrew Elsinore Thread

    Hello. This afternoon I made ​​a battery of tests. 1 / With I = 0 and D = 0 constants, I climbed slowly up the value of P 15. Then I dropped it to 12, because 15 was too much inertia and it passed by the target temperature. 2 / P = 12 and D = 0 constants, I have increased...
  4. C

    NEW StrangeBrew Elsinore Thread

    Hello. I've done another test with the values​​: -set point 50 -Duty time 2 -p 1 -i 0 d 0 Everything runs very slow. Something that directly takes about 3 minutes with this setup takes more than half an hour. The temperature curve rises moderately, and then...
  5. C

    NEW StrangeBrew Elsinore Thread

    Hello. This night I make a new test. I set point to 28ºC (28ºC=82ºF). I have waited if stopped to 28 or 82 but that points has arrived and has not stopped. At the end I stopped at 95ºC, but the system was still giving power to the resistance.
  6. C

    NEW StrangeBrew Elsinore Thread

    Ok. I change P value to 1. ¿Any suggest for P,I,D testing values, for use with 10 galons init kettle? This night I try again with new P value. Yes.'s It. Put an option in edit mode. To make it optional. Greetings
  7. C

    NEW StrangeBrew Elsinore Thread

    Hi, thanks for the clarifications. I've done the first water test. The settings that I used: Auto set point 65 duty time 2 p 44 i 165 d 4 The problem is that has not stopped heating or at 65 or at 70 ° C and the temperature continued ascending. I stop manually in 80ºC I...
  8. C

    NEW StrangeBrew Elsinore Thread

    All right! is now operational! Thanks. A couple of things: 'In the auto button is a "set point", I guess that is the target temperature. But in the manual button no this. In manual button to put the target temperature I need to configure a step mash. Is there any difference being step...
  9. C

    NEW StrangeBrew Elsinore Thread

    Hello. I run with console in crhome: Uncaught Typerror: cannot read property 'style' of undefined (for all 4 buttons) pidFunctions.is:587 (when I push button auto) pidFunctions.is:649 (when I push button manual) pidFunctions.is:618 (when I push button hysteria) pidFunctions.is:556 (when I...
  10. C

    NEW StrangeBrew Elsinore Thread

    Ok. This night I look browser console. Don't problem, I make spanish translation. Say me when is ok.
  11. C

    NEW StrangeBrew Elsinore Thread

    Hello. Thanks for the changes. Now changing degrees C to F works perfectly and the temperature is shown in C once configured. Inverting outputs seems to work fine, but I could not fully test it, because there is a failure to execute the pid, both manual and auto .. I had to make a small...
  12. C

    NEW StrangeBrew Elsinore Thread

    Hello. Congratulations on your hard work. I'm trying Elsinore and I need some help: -How I can put the temperature in Celsius degrees? -How I can invert outputs to use with a relay board instead of ssr for testing? I see: "You'll need to add -Dinverted_outputs", for exchange output...