I would like to use the Thermoworks Pro-Series Needle Probe with the Rex c-100 PID. The manual says that the device uses a thermistor. Does anybody know the settings for the PID that will make it work with this probe?
thanks!
I bought the first unit (C100) about two years ago and it didn't have an SSR. I had to open it up, remove the physical relay and wire the connections closed so it could output to an SSR. It wasn't difficult and I posted detailed instructions with pictures earlier in this thread. It may have...
Morzh,
I also noticed that the controller reacted quite slowly. I believe that is to preserve the mechanical relay that it is meant to control. However, the unit is not actually as primitive as I first thought. If you go into the settings menu, there is a setting displayed as "ArU" which a...
I succeeded in using the REX-C100 to operate an SSR also. I removed a relay and ran the switching signal straight to the terminal posts. Here is a PDF with before and after pics: http://www.mediafire.com/?bbqzfm58c7lpsbo