Forum: Electric Brewing 09-17-2014, 07:55 PM
Replies: 18
Views: 1,433
Posted By Brumateur
If you are looking for not very expencive entry...

If you are looking for not very expencive entry level controller I can suggest mine - http://www.ebay.ca/itm/221402670805
Forum: Electric Brewing 09-11-2014, 08:13 PM
Replies: 8
Views: 223
Posted By Brumateur
You don't need to bend an element it should goes...

You don't need to bend an element it should goes through nut easily.
Forum: Electric Brewing 09-10-2014, 10:46 PM
Replies: 18
Views: 668
Posted By Brumateur
Even 24awg wire is OK for PID wiring.

Even 24awg wire is OK for PID wiring.
Forum: Electric Brewing 09-04-2014, 10:25 PM
Replies: 12
Views: 1,807
Posted By Brumateur
It's not true. To get the same wattage at 240V...

It's not true. To get the same wattage at 240V you need a half of current in comparison to 120V
Forum: Electric Brewing 08-20-2014, 07:56 PM
Replies: 10
Views: 917
Posted By Brumateur
Sure it will. The one issue - potentiometer will...

Sure it will. The one issue - potentiometer will work only a half way. On a first half turn (starting from the minimum) you will have no output.
Forum: Electric Brewing 08-19-2014, 08:09 PM
Replies: 10
Views: 917
Posted By Brumateur
Yus you can , just use a 270K potentiometer.

Yus you can , just use a 270K potentiometer.
Forum: Electric Brewing 08-18-2014, 05:57 PM
Replies: 2
Views: 168
Posted By Brumateur
What is your PID model?

What is your PID model?
Forum: Electric Brewing 08-18-2014, 05:45 PM
Replies: 9
Views: 359
Posted By Brumateur
Are you sure about PID failure? More likely you...

Are you sure about PID failure? More likely you have a failed SSR.
Forum: Electric Brewing 08-16-2014, 08:29 PM
Replies: 9
Views: 359
Posted By Brumateur
Some temperature probes are not really water...

Some temperature probes are not really water tight. So some omount of liquid can get in IDE. And its causing wrong temperature reading.
Forum: Electric Brewing 08-15-2014, 12:58 AM
Replies: 4
Views: 275
Posted By Brumateur
I'd still recommend to spend a few more dolalrs...

I'd still recommend to spend a few more dolalrs and buy 22 or 18AWG wire. It saves you a lots of wiring efforts.
Forum: Electric Brewing 08-15-2014, 12:56 AM
Replies: 7
Views: 258
Posted By Brumateur
Can you reset it when no load connected?

Can you reset it when no load connected?
Forum: Electric Brewing 08-14-2014, 09:23 PM
Replies: 18
Views: 746
Posted By Brumateur
GFCI will not trip since in/out balance will not...

GFCI will not trip since in/out balance will not be broken.
Forum: Electric Brewing 08-14-2014, 07:55 PM
Replies: 10
Views: 917
Posted By Brumateur
If you don't need a fancy dial you can go even...

If you don't need a fancy dial you can go even cheaper

http://www.ebay.com/itm/AC-25-380V-Solid-State-Relay-Voltage-Resistance-Regulator-40A-w-Black-Heat-Sink-/230914765232 ...
Forum: Electric Brewing 08-14-2014, 07:45 PM
Replies: 10
Views: 917
Posted By Brumateur
Diagram with a switch:

Diagram with a switch:
Forum: Electric Brewing 08-14-2014, 07:39 PM
Replies: 10
Views: 917
Posted By Brumateur
If you are looking for cheapest controller...

If you are looking for cheapest controller possible you need

http://www.ebay.com/itm/1pc-KYOTTO-AC-Solid-State-Relay-SSR-KR2040AX-280VAC-40A-VR-to-AC-/140553987088...
Forum: Electric Brewing 08-14-2014, 04:27 AM
Replies: 19
Views: 1,532
Posted By Brumateur
I wouldn't do it. Yes you are replaced a breaker...

I wouldn't do it. Yes you are replaced a breaker to handle 30A but wiring still is for 15Amp. Yes National Electrical Code is very conservative so most likely your 15A rated wiring will handle 22A...
Forum: Electric Brewing 08-13-2014, 11:21 PM
Replies: 3
Views: 386
Posted By Brumateur
Try to set an "I" parameter to 1.

Try to set an "I" parameter to 1.
Forum: Electric Brewing 08-13-2014, 02:39 AM
Replies: 19
Views: 1,532
Posted By Brumateur
It's not simple it's extremely simple. You don't...

It's not simple it's extremely simple. You don't need even a relay. Just two 120V lives connected to different phases.
Forum: Electric Brewing 08-11-2014, 05:57 AM
Replies: 32
Views: 5,380
Posted By Brumateur
Connection to 10 required if you have 4 wires...

Connection to 10 required if you have 4 wires PT-100 probe.
Forum: Electric Brewing 08-11-2014, 02:26 AM
Replies: 8
Views: 232
Posted By Brumateur
it's enough to switch only one wire

it's enough to switch only one wire
Forum: Electric Brewing 08-11-2014, 02:23 AM
Replies: 32
Views: 5,380
Posted By Brumateur
Your diagram is correct. Though you dont need the...

Your diagram is correct. Though you dont need the green jumper wire.
Forum: Electric Brewing 08-09-2014, 01:04 AM
Replies: 14
Views: 773
Posted By Brumateur
Do you mind to read my post located just above...

Do you mind to read my post located just above your question?

This 3A at the switch spec is chinese 3A. I wouldn't trust this.
Forum: Electric Brewing 08-07-2014, 10:26 PM
Replies: 3
Views: 195
Posted By Brumateur
How about this one ...

How about this one
http://www.ebay.com/itm/ON-OFF-ON-3-Positions-Changeover-Rotary-Cam-Switch-AC-660V-25A-Amp-/231299226200
Forum: Electric Brewing 08-07-2014, 05:32 AM
Replies: 16
Views: 1,810
Posted By Brumateur
Anu 120V 20A rated SPSS switch is OK like...

Anu 120V 20A rated SPSS switch is OK

like this one

http://www.homedepot.com/p/Gardner-Bender-20-Amp-Single-Pole-Toggle-Switch-GSW-11/100030219

or even this one
...
Forum: Electric Brewing 08-06-2014, 08:39 PM
Replies: 14
Views: 773
Posted By Brumateur
I have a few same switches in my possession. Yes,...

I have a few same switches in my possession. Yes, they marked 3Amp, but I wouldn't trust that rating considering how this switch is manufactured. It's a very fragile.
Showing results 1 to 25 of 339


 