  • Posted in thread: NEMA Power Inputs on 09-14-2014 at 04:27 PM
    Thanks all for the good advice. I will use the L14-30 inlets for their flexibility. These are
    being used for power in only.I think the L6-30 would work fine wired as hot/neutral/ground for
    the 120V ho...

  • Posted in thread: NEMA Power Inputs on 09-13-2014 at 09:37 PM
    I need flanged inlets for my control panel. I'm currently using 2x 2000W 120V elements with no
    control panel. I'd like to use an inlet that would still work if I move and have 240V
    available.Can I use...

  • Posted in thread: 2 RTD temp probes, 1 PID on 04-22-2013 at 10:36 PM
    ikonis, can you tell me more about that multi-contactor switch you've got in your picture? I
    want to do this exact same config.All the selector switches I've seen come with 2 blocks. Did
    you find one ...

  • Posted in thread: Dual input, 4 element question on 04-16-2013 at 03:43 AM
    OK, here's my fix. think I have to switch after the load or else I won't be able to have one
    element in each vessel powered on.For the switch, I was actually planning on using something
    like this: I...

  • Posted in thread: Newb...2 elements 1 ssr, where did i go wrong? {help} on 04-15-2013 at 08:18 AM
    What heat sink are you using? May be that it's too small or you don't have enough air flow
    around it. Is the sink inside an enclosure?

  • Posted in thread: Dual input, 4 element question on 04-15-2013 at 02:33 AM
    That's a great idea with the dual out SSRs. I already have several MGR-1 D4825 SSRs so I will
    make use of those.How does this first draft wiring diagram look? I'm going with 4 SSRs but
    otherwise tryin...

  • Posted in thread: Dual input, 4 element question on 04-12-2013 at 01:19 AM
    What are you using to make the wiring diagram picture? That looks incredibly useful.

  • Posted in thread: Dual input, 4 element question on 04-12-2013 at 01:08 AM
    jeffmeh, I agree with this 100%. Will do. To add to my earlier post, I think you should come up
    with a design that:1) Allows you to shut all elements off for safety using mechanical switches
    or relays...

  • Posted in thread: Dual input, 4 element question on 04-10-2013 at 11:30 PM
    Thanks to all for your replies. machfive55, I see what you're saying but that gets me to having
    6 relays (2 SSR + 4 mechanical). I guess I'd probably go for the 4 SSRs instead to minimize
    wiring and f...

  • Posted in thread: Dual input, 4 element question on 04-10-2013 at 03:15 PM
    I want to run 2x 120V 20A inputs into 2 2352 controllers. Controller 1 is for the HLT and
    controller 2 is for boil kettle. From each controller I want to run 2x 1650w elements.I want
    flexibility to ha...