  • Posted in thread: Selling it all!!! on 03-07-2016 at 08:33 PM
    Sounds like my guy might be rethinking.

  • Posted in thread: Selling it all!!! on 03-01-2016 at 04:48 PM
    Can you pm me a phone number. Might have a buyer in PGH. for whole system.

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-27-2016 at 01:45 AM
    It did power up in run mode even after being off for a few hours.... I think We are going to
    leave all this stuff in tact and just keep the temp probe warmer than 64*

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-27-2016 at 01:40 AM
    the fan motor looks easy. that is the three wires on the right (low, High, Turbo) Not sure
    why they ran a seperate wire for each speed yet though. Yellow wire up top is labled COMP L1
    goes to the Ca...

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-26-2016 at 09:53 PM
    But if you just relocate the probe from the coils it works fine and you won't have to dick with
    heaters for it.Edit: and to control the AC unitthis is true as long as my garage is over
    64*(lowest se...

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-26-2016 at 09:46 PM
    that cool bot thing is pretty "cool" but over $300 ouch lol. guess this might not be as easy as
    i was hoping it was. I can essentially build the same device for about $75 with a johnson A419
    and the w...

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-26-2016 at 09:25 PM
    I would still want thermo control to hold it at 35* or whatever. But I'm guessing the AC's
    controller already has a built in short cycle timer just need a mechanical on off for the temp
    probe.

  • Posted in thread: DIY chiller control, can I just use the temp probe? on 02-26-2016 at 09:12 PM
    I am building a Chiller out of a spare AC I had around currently I have it runnning by putting
    the temp probe in front of a space heater... On eco mode it runs perfectly. shuts off the
    condenser fan a...

  • Posted in thread: Brewers Hardware 15 Gallon Jacketed Unboxing on 01-15-2016 at 10:05 PM
    About the 7 gallon mark.... But I have an idea about this. There is a spare 1.5" triclamp port
    in the lid. If I get a nice long thermowell I can reach down from the top for the jacket pump.
    I haven't ...

  • Posted in thread: CO2 Leak detector - inline on 12-07-2015 at 05:21 PM