LATEST ACTIVITY

  • Posted in thread: 110v Recirculating eBIAB 2.5 gallon batches on 03-04-2013 at 02:40 PM
    Well I have finally gotten the bugs worked out of my wiring job :rockin: and was able to get a
    brew in yesterday on the new rig!! I brewed up a SMaSH with Marris Otter and Citra, can't wait
    for this t...

  • Added a new Photo on 03/04/2013

  • Added a new Photo on 03/04/2013

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-26-2013 at 01:20 PM
    Thanks russki, I actually have gone back and printed out some pictures of your wiring and have
    found the error in my ways. I have also been able to find a diagram from our very own P-J that
    gives me m...

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-25-2013 at 02:29 PM
    Hey russki, could you take a picture of your wiring for me? I'm thinking I may have my
    contactors wired incorrectly. I'm assuming that the coil in the diagram is the little block off
    to the side on th...

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-17-2013 at 09:06 PM
    The E-Stop from Auber Instruments comes with a N/O and a N/C switch module. You need to order
    an additional N/O switch module and replace the N/C module in the switch. You might call Auber
    and see if ...

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-17-2013 at 08:44 PM
    That is a major issue. The E-Stop, as it is set up, must have 2 N/O contact blocks for it to
    function properly. The panel will not operate properly otherwise.Dang it, well that stinks.
    When I bought t...

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-17-2013 at 06:43 PM
    Very bad idea. You are playing "You bet your life."!Dually noted, I will look in to changing
    this.

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-17-2013 at 06:18 PM
    I know it does not address your problem, but it would be much safer to use a flanged inlet for
    your power feeds into the box. As it is, you will have live male plugs. Not a great idea.I
    understand the...

  • Posted in thread: Problems With Dual 120V Input, Dual Element BIAB on 02-17-2013 at 06:10 PM
    I used this exact diagram for my build, and had no issues. Just a thought - are both contact
    blocks in your e-stop NO? I think Auberins e-stop ships with one NO and one NC - that would
    certainly cause...