  • Posted in thread: March 815 ss flow issue (primes fine) on 11-13-2013 at 03:07 AM
    Thanks! To do it again, I would definitely cut the hole for the magnet as you suggest. It
    wasn't that hard to monkey with the magnet though after you told me how to set it.

  • Posted in thread: New Temperature Controller on 11-13-2013 at 02:46 AM
    Yes, and I like it a lot. Yes it does have an anti-short (compressor delay) function. You can
    download the manual on the product page to look at all the features.I have mine set to 1 degree
    over and u...

  • Posted in thread: HLT herms coil doubled as wert chiller? on 11-06-2013 at 02:10 AM
    Cj. Thats awsome. How fast does it drop it down? Also, do you have to add more ice or change
    the water?Took about 5-6 minutes to go from boil to 140 if I remember right. Another 5-6 to get
    under 110. ...

  • Posted in thread: March 815 ss flow issue (primes fine) on 11-05-2013 at 02:41 AM
    I owe it to Walter to put up a few pictures. I adjusted the magnets forward and boy do those
    pumps move some water. 9 gallons in 65 seconds on Pump 1 (camlock qd), 68 seconds on Pump 2
    (ball bearing s...

  • Posted in thread: HLT herms coil doubled as wert chiller? on 11-05-2013 at 12:52 AM
    I do it (25 ft 1/2" stainless). Not quite as fast as my old IC (50 ft 3/8" copper) but also one
    less piece of equipment. I fill HLT with cold water and ice cubes. This is only 6.5 gal of wort
    though.

  • Posted in thread: March 815 ss flow issue (primes fine) on 11-04-2013 at 03:19 PM
    Had a lengthy chat with Walter at March. I can't praise him enough for his knowledge and
    patience.So the magnet sits on the magnet shaft at a precise location relative to yhe pump head
    and impeller. I...

  • Posted in thread: Chugger Pump Just Stops During Recirculation on 11-03-2013 at 06:31 PM
    Sounds very much like my March pump problem I posted yesterday. Hmm...

  • Posted in thread: March 815 ss flow issue (primes fine) on 11-03-2013 at 12:46 AM
    This is the stainless head with 3/4" center inlet. For a year now, the pump primes fine and
    will pump with ball valve 0-60% open. Any more than that and the water stops moving.I have the
    same qd's as ...

  • Posted in thread: Perlick 525 SS faucet leaks on 10-24-2013 at 02:25 AM
    Well I read through this whole thread. Went to look at the mentioned VentMatic and find this.
    Sounds very similar to the Perlick issue."NOTICE:VERSION CHANGE - 2013/10/15We are now on
    "VentMatic 1.1"....

  • Posted in thread: Just finished my HERMS controller on 10-21-2013 at 09:29 PM
    I second that request. I would love to see these images.