Spike Brewing 12.5 Conical Fermenter Giveaway - Enter Now!

Home Brew Forums > Home Brewing Beer > DIY Projects > Using Paintball Remote Line as a Cheaper CGA 320 High Pressure Hose

Reply
 
LinkBack Thread Tools
Old 04-13-2012, 01:43 PM   #1
Moj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2012
Location: NYC, NY
Posts: 4
Default Using Paintball Remote Line as a Cheaper CGA 320 High Pressure Hose

I have a Micromatic Regulator and a 20 lb. CO2 tank. My goal is to connect them with a high pressure hose similar to this one, but I wanted to do it for a lot less money. I bought a paintball remote line for approximately one third of the price.

My problem is that the remote connects nominally to the tank and the regulator; however, it leaks. A lot. The threads on the remote line are exactly the same as the CGA-320 threads of the tank/regulator, but the end of a paintball valve isn't threaded, allowing the paintball tank to seal with an o-ring, where a washer would be needed for the regulator. Also, the paintball remote has a tiny hole to release pressure on the female side that leaks some CO2.

I don't have a washer between the tank and the remote, and I'll try to go pick one up today, but I wanted to check if anyone has had success with this.

Thanks in advance for any assistance!

P.S. I realize that, with some different tweaks, I could run a low pressure line in from a primary on the tank to the rest of the regulator bank, but I would prefer to do it the way I described above.

__________________
Moj is offline
 
Reply With Quote Quick reply to this message
Old 04-13-2012, 04:02 PM   #2
o2nut
Feedback Score: 0 reviews
Recipes 
 
Join Date: Sep 2008
Location: San Luis Obispo
Posts: 23
Liked 1 Times on 1 Posts

Default

The paintball fittings will fit industrial co2 fittings sum what. Where they fail is exactly where you are having problems. My suggestion would be to use just the hose. Depending on your regulator, some are LH threads verses RH threads, you can remove the nut and nipple from the regulator and use that on your 20lb tank and put the hose in between. If it is a LH thread you will prob be out of luck unless you can find an adapter online. Not knowing what kind of connections that are on the paintball remote hose you may need some adapters. Quick caution on the adapters: buy them form your welding supply, they will have ones that are rated for 3000psi. The ones at hd are rated for 2-300 psi. If all else fails you might find some adapters like these:

http://www.amazon.com/AQUATEK-CO2-Paintball-Tank-Adapter/dp/B004M49QDC/ref=sr_1_1?s=sporting-goods&ie=UTF8&qid=1334332427&sr=1-1

http://www.amazon.com/Western-Enterprises-SEPTLS312CO4-Regulator-Nipples/dp/B002BXZNRO/ref=sr_1_cc_1?s=aps&ie=UTF8&qid=1334332643&sr=1-1-catcorr

http://www.amazon.com/Western-Enterprises-SEPTLS312CO2-Regulator-Inlet/dp/B002BY24E8/ref=pd_sim_sbs_hi_6

Prob also need a western enterprise bf-4-2hp.

Hope this helps

__________________
o2nut is offline
Moj Likes This 
Reply With Quote Quick reply to this message
Old 04-13-2012, 04:11 PM   #3
zachattack
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2012
Location: , MA
Posts: 2,456
Liked 234 Times on 202 Posts
Likes Given: 124

Default

Maybe this is a silly question, but why would you want to add line to the high pressure side? Why not do it after the regulator? Seems safer.

__________________
zachattack is offline
 
Reply With Quote Quick reply to this message
Old 04-13-2012, 04:25 PM   #4
phoenixs4r
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jun 2011
Location: Hayward, California
Posts: 1,506
Liked 54 Times on 49 Posts
Likes Given: 38

Default

I believe your issue is with the tank. Typical paintball tanks have a pin that you need to depress before co2 starts flowing. When the on/off valve is turned on, it depresses the pin on the tank, whilst closing off pressure relief holes to allow the flow from the tank down the line. When you turn he valve off, it releases pressure on the pin, closing the source of the co2 from the tank, while opening relief holes to allow remaining pressure to escape, allowing safe removal of tank. They do this because paintball tanks have their connector threaded to the tank itself, and there have been cases where instead of loosening from the on/off valve, the connection gets removed from the tank and turns into a rocket.

Try turning the on/off to on before opening the tank valve, it should not leak. It also completely renders the on/off valve on the hose side completely useless, u will have to control on l/off of gas flow via the tank.

phoenixs4r is offline
Moj Likes This 
Reply With Quote Quick reply to this message
Old 04-13-2012, 05:54 PM   #5
Moj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2012
Location: NYC, NY
Posts: 4
Default

Quote:
Originally Posted by o2nut View Post
My suggestion would be to use just the hose. Depending on your regulator, some are LH threads verses RH threads, you can remove the nut and nipple from the regulator and use that on your 20lb tank and put the hose in between. If it is a LH thread you will prob be out of luck unless you can find an adapter online. Not knowing what kind of connections that are on the paintball remote hose you may need some adapters.
Thanks. This is spot on. Just came back from the welding shop, and there is no way to do what I want to do without replacing some parts. Putting the hose between the existing regulator parts was a great idea. If my regulator was right hand threaded, it would be easier. Because it is left hand, and the hose is right hand, I'll need one coupler that goes from Female 1/4" LHT NPT (Tank Nipple) to Female 1/4" RHT NPT (hose) and another coupler that goes from Male 1/4" LHT NPT to Male 1/4" RHT NPT.

Looked for a bit, but I'm not sure if these couplers exist. I'll check more later tonight.

Thanks to all who responded!
__________________
Moj is offline
 
Reply With Quote Quick reply to this message
Old 04-13-2012, 06:36 PM   #6
Moj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2012
Location: NYC, NY
Posts: 4
Default

Just an update. Went to the welding store with all the fittings. Bottom line is this is probably not possible with left-handed regulator threads, due to the lack of fitting availability. Probably doable with right handed threads. Also, lack of an easily available male CGA 320 connector precludes using the CO2 tank fittings on both sides.

Bottom line, probably easier to buy the hose.

Thanks again to everyone.

__________________
Moj is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
understanding high pressure versus low pressure propane BucksPA DIY Projects 122 04-05-2014 08:53 PM
diy remote keezer to taps glycol line cooler? doctorsbro DIY Projects 2 04-21-2011 02:16 AM
High Pressure Washer hose for CFC milldoggy DIY Projects 5 01-20-2011 03:24 AM
Where to find high pressure propane hose (18") ghart999 DIY Projects 2 04-22-2010 02:56 PM
high pressure propane burner for low pressure application? schristian619 DIY Projects 4 04-16-2010 03:15 PM