I posted this is the 'automated brewing' subforum, but thought I'd post it here too since most of you have been using this exact model.
I can't get any gas through the VR8200 furnace valve. below is my post from yesterday:
---------------
I've got pilot lights on the HLT and MT no problem, but I can't get the honeywell solenoids to fire when given 24 vac. I've taken readings at all the right spots in my build and gotten the right voltage (28vac coming off the 24V transformer I'm using) and things are wired properly.
I'm using this regulator at the tank
http://www.tradezz.com/buy_3055290_Low-Pressure-Regulator.htm sold at home depot under the brinkmann name. seems like everything should work fine, but I get no gas through the regulator at all upon the 24vac call for it.
the regulator is 11" WC which should be no problem... my BG14 burners have been converted to LP (the BK burner, which is just on a 1-30 psi regulator so I have some control works just fine) but I'm totally stumped at this point.