Ss Brewing Technologies Giveaway!

Home Brew Forums > Home Brewing Beer > DIY Projects > Grounding questions
Reply
 
LinkBack Thread Tools
Old 11-27-2010, 04:36 AM   #1
Maltose
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2010
Location: Frederick, MD
Posts: 470
Liked 2 Times on 2 Posts
Likes Given: 1

Default Grounding questions

I've got a stainless single tier with two pump mounts, also stainless, welded to the lower beam. I've also got a control panel that will be mounted on a wall beside the stand. The stand is located in my basement. I'm wondering how to safely ground both the pumps and the CP. I'm planning on mounting a small two position terminal strip on the underside of my mounts, then run the wires from the pump to the CP via wire tubing. The grounds would be directly mounted to the stainless pump mounts.

Here's my question. Would it be safer to mount the pump grounds to the stand, or run a ground wire with the pos. and neg. to the CP, and ground it with all the rest of my components in my CP?

__________________
Maltose is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 02:20 PM   #2
CollinsBrew
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
CollinsBrew's Avatar
Recipes 
 
Join Date: Mar 2007
Location: Jacksonville, FL, Florida
Posts: 422
Liked 3 Times on 3 Posts

Default

If you ground it to the stand, what will the stand be grounded to? If you touch the stand, you could be the ground. Or, if you touch the stand and another electrical component, you could complete a circuit and get a nice jolt. Fortunately, the few times it's happened to me over the years, I haven't died from it. I'd run everything I could to a common ground.

__________________

Flying, golfing, boating and brewing. The first is my job. The other three I wish were my job.

“I like beer. On occasion, I will even drink beer to celebrate a major event such as the fall of Communism or the fact that the refrigerator is still working.”

Single Tier Wooden Brutus build

CollinsBrew is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 02:52 PM   #3
Maltose
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2010
Location: Frederick, MD
Posts: 470
Liked 2 Times on 2 Posts
Likes Given: 1

Default

So wire the pumps to a common ground and run a wire from the ground strip to the stand to ground it as well?

__________________
Maltose is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 06:06 PM   #4
trigger
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2010
Location: portland
Posts: 628
Liked 5 Times on 5 Posts
Likes Given: 2

Default

You should definitely ground your stand. Once you have a ground run to the stand there's really no reason why you can't use the stand as your common ground and save yourself from running the extra wire.

__________________
trigger is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 06:18 PM   #5
Dunerunner
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2010
Location: Florence, OR
Posts: 831
Liked 12 Times on 11 Posts
Likes Given: 29

Default

Let's talk Hot (Black), Neutral (White) and Ground (Green). Everything, as trigger says, should have a common ground. That would be the Green or bare copper wire which could be attached directly to the control panel housing, the panel then being connected (welded) to the brew stand.

Running the B,W,G wires for your pumps back to the control panel and attaching the Neutrals (if un-switched) and connecting the (Green) grounds to a grounding buss or to the panel would suffice. It is assumed the Hot (Black) will be switched.

Be sure your receptical ground is properly connected to the grounding buss in the Main Distribution Panel. If not, the whole system floats at some potential above ground and you will get bit!!

__________________
Dunerunner is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 06:39 PM   #6
Yuri_Rage
Gritty.
HBT_MODERATOR.png
Feedback Score: 0 reviews
 
Yuri_Rage's Avatar
Recipes 
 
Join Date: Jul 2006
Location: Southwest
Posts: 13,916
Liked 607 Times on 376 Posts
Likes Given: 54

Default

To piggyback on Dunerunner's post,

If you have two wire pumps (i.e., hot and neutral are the only wires going to a two pronged plug), DO NOT wire the neutral as if it's a ground by connecting it to your stand. That would mean that the current path would flow through your stand any time the pumps run - not good. Instead, wire the hot and neutral lines to the black/white wires, respectively, coming from the outlet in the wall. Switch the hot wire in your control panel. Ground the frames of the pumps by connecting them to your stand, which should be grounded.

If the cords include a green ground wire, follow Dunerunner's post.

__________________
Homebrewed Blog..........YouTube Channel .......... Shirts, posters, etc
Yuri_Rage is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 06:43 PM   #7
Dunerunner
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2010
Location: Florence, OR
Posts: 831
Liked 12 Times on 11 Posts
Likes Given: 29

Default

Good point Yuri! Never considered a two wire pump motor....my bad!

__________________
Dunerunner is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 07:34 PM   #8
Maltose
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2010
Location: Frederick, MD
Posts: 470
Liked 2 Times on 2 Posts
Likes Given: 1

Default

Quote:
Originally Posted by Yuri_Rage View Post
To piggyback on Dunerunner's post,

If you have two wire pumps (i.e., hot and neutral are the only wires going to a two pronged plug), DO NOT wire the neutral as if it's a ground by connecting it to your stand. That would mean that the current path would flow through your stand any time the pumps run - not good. Instead, wire the hot and neutral lines to the black/white wires, respectively, coming from the outlet in the wall. Switch the hot wire in your control panel. Ground the frames of the pumps by connecting them to your stand, which should be grounded.

If the cords include a green ground wire, follow Dunerunner's post.
The pumps are March 809HS. It has a black, white and green wire (hot, neutral, ground respectively). I'm thinking of putting a small two position strip underneath my pumps, then connect a black wire and white wire to this strip to then run to the CP. The ground wire could be mounted to the pump mount that is welded on the stand IF the stand is grounded, yes?
__________________
Maltose is offline
 
Reply With Quote Quick reply to this message
Old 11-27-2010, 09:40 PM   #9
CollinsBrew
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
CollinsBrew's Avatar
Recipes 
 
Join Date: Mar 2007
Location: Jacksonville, FL, Florida
Posts: 422
Liked 3 Times on 3 Posts

Default

If you ground the stand somehow then yes. Otherwise, like I said before, you could potentially become the ground which = bad day.

__________________

Flying, golfing, boating and brewing. The first is my job. The other three I wish were my job.

“I like beer. On occasion, I will even drink beer to celebrate a major event such as the fall of Communism or the fact that the refrigerator is still working.”

Single Tier Wooden Brutus build

CollinsBrew is offline
 
Reply With Quote Quick reply to this message
Old 11-28-2010, 07:19 AM   #10
Maltose
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2010
Location: Frederick, MD
Posts: 470
Liked 2 Times on 2 Posts
Likes Given: 1

Default

Would a ground wire welded to the frame, then running to the ground bar in the CP (grounded to the house service ground) work? Otherwise, in a basement with a concrete floor, what is my best option for grounding the stand?

__________________
Maltose is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
Element Grounding zGrubermeister DIY Projects 31 08-03-2010 06:39 PM
Brutus Grounding Question BigBobsBrews DIY Projects 2 04-19-2010 06:57 PM
Grounding a heating element? rynd96 DIY Projects 9 03-07-2010 11:50 PM
Grounding\Wiring questions on HERMS setup smuth10 DIY Projects 9 02-26-2010 05:59 PM