bsomogyi 04-03-2013 01:48 AM

Center Inlet Chugger Pumps Mounting
 
1 Attachment(s)
Anyone have any advice for mounting these pumps? I'm going to hard plumb between three of the pumps on the same horizontal plane, with electronic valves to control flow. However, the outlets are slightly off from 90 degrees (see image of pump), which will cause issues when trying to run SS pipe between each fitting. Should I fabricate a mounts on my stand that are at an angle for the pump to bolt into, or maybe a welded mount, but use washers to introduce an angled to the mounted pump. Hope I'm making sense.. Any thoughts?

mattd2 04-03-2013 02:22 AM

Have you checked that the base can not be lossened and the pump rotated so the outlet is vertical? Just going of pictures on the chugger website that show all their centre inlets having the outlet vertical.

bsomogyi 04-03-2013 02:33 AM

The base is welded to the cylinder. I also tried to change the pump faceplate in all four rotated configurations and none of the configurations allow a vertical outlet without needing to do some kindof mounting trickery.

mattd2 04-03-2013 02:50 AM

That Sucks, have you though about checking with Chugger if that is normal?
If you going to use those pumps I would make the mounts level and go with the washer/shim approach. That way if you ever need to replace a pump and the new one is not on the piss it won't be a major PITA

bsomogyi 04-03-2013 02:55 AM

I've sent an email to chugger explaining the issue, with a link to this thread. Well see if I get a response via email or on this thread. Good call on the washer approach, maybe being the better of the two options in the long run. Thanks.

mattd2 04-03-2013 06:45 AM

From what I have seen Chugger is pretty good with their customer service. I am stoked that they now stock a 230V pump and seem to do international shipping. Good luck!

tophmck 04-03-2013 11:41 AM

I had a problem once and e-mailed Chugger. No response. But then I called and they were very responsive.

chuggerpumps 04-03-2013 01:44 PM

Chugger Questions
 
If anyone has any questions on Chugger Pumps you can contact us in any of the following ways

Phone: 1-800-810-1053

email:

mike@chuggerpumps.com

Facebook:

Chugger pumps

We will respond within 5 minutes....if you don't get a response to an email call it may get spammed...it happens. lease do not use HBT to contact us as we do not follow all the time

chuggerpumps 04-03-2013 01:55 PM

Please call me ...800-810-1053 MIKE ....We have never seen this before. It looks like the cord is wrapped on the base? Please show a pic with the cord unwrapped?

samuryan 04-03-2013 04:26 PM

my chugger center inlet points straight up, no angle whatsoever