Happy HolidaySs Giveaway - Winners Re-Re-Drawn - 24 hours to Claim!

Get your HBT Growlers, Shirts and Membership before the Rush!


Home Brew Forums > Home Brewing Beer > All Grain & Partial Mash Brewing > E-HERMS: Compensating for fluid volume in plumbing
Reply
 
LinkBack Thread Tools
Old 03-06-2012, 05:06 AM   #1
BrewinBigD
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Stratham, NH
Posts: 276
Liked 6 Times on 5 Posts

Default E-HERMS: Compensating for fluid volume in plumbing

SO the E HERMS build is finally complete. This weekend I'll be dialing in my Temp controllers, Graduating my sight guages, and doing a wet run through with plain water to see how everything flows.

I usually mash at 1.25lb/qt, but im thinking that may be too thick for the reason that the wort mus make it all the way through the system before returning tothe tun, my original plan was to mash in at the original thickness, then at sparge use the sparge water to flush the last of the wort through the HERMS into the MT.

should i try this on my first brewday and se how it comes out? im a stickler about wanting to hit all my numbers right and dialing in the system for maximum brewhouse efficiency.
As far as adding this (possible) extra water into beer smith, should i just up my MT deadspace or try increasing my overall boil volume??

__________________
BrewinBigD is offline
 
Reply With Quote Quick reply to this message
Old 03-07-2012, 01:41 AM   #2
BrewinBigD
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Stratham, NH
Posts: 276
Liked 6 Times on 5 Posts

Default

.

__________________
BrewinBigD is offline
 
Reply With Quote Quick reply to this message
Old 03-07-2012, 02:20 AM   #3
milldoggy
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2008
Location: Pottstown, Pa
Posts: 2,038
Liked 62 Times on 51 Posts
Likes Given: 2

Default

How long are you hoses and coils? I think mine is around 1/2 to 1/4 gallon. What I do is fill mt htl and mlt with water. Turn on pumps and heater. So I use the herms to heat my strike water. If you do this, you will see how much deadspace you have. I use a calibrate diptube to see the diff. Also, I use 1.5 as a ration and keep things more fluid.

__________________
My E-Herms

My hop stopper
milldoggy is offline
 
Reply With Quote Quick reply to this message
Old 03-07-2012, 05:55 AM   #4
BrewinBigD
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Stratham, NH
Posts: 276
Liked 6 Times on 5 Posts

Default

Id guess my plumbing holds about a half gallon. My herms is 1/2ID x 20 ft and about 6 feet total of silicone tube(1/2"). I was thinking that mashing a little thinner would help. I guess my real first concern is keeping enough water on the grain for the entire mash to acheice the best efficiency. I cant wait to get my equipment dialed in to beersmith to get a baseline efficiency number that i can live with.

__________________
BrewinBigD is offline
 
Reply With Quote Quick reply to this message
Old 03-08-2012, 01:21 AM   #5
ellijo89
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2009
Location: Kennewick, WA
Posts: 116
Liked 2 Times on 2 Posts

Default

I have an E-Herms and all I do is I have marks in my mash tun for water levels, I fill it up a bit over that, then turn the pump on and instead of having it recirc and flow back into my mash tun I have the last hose go into a pot. This cleans out my lines a bit, just in case, and it fills my hoses, so that when I hit the right level, I stop my pump, and I have the correct water amount, and my hoses are full. Then I just start it heating for mash in. Hope that helped... if it made any sense haha.

__________________
ellijo89 is offline
 
Reply With Quote Quick reply to this message
Old 03-08-2012, 02:02 AM   #6
BrewinBigD
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Stratham, NH
Posts: 276
Liked 6 Times on 5 Posts

Default

It does. I think until i master my setup im gonna thin the mash down to 1.5qt/lb. Which should fill my lines if im brewing a mid OG beer.

__________________
BrewinBigD is offline
 
Reply With Quote Quick reply to this message
Old 03-08-2012, 10:35 PM   #7
flananuts
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
flananuts's Avatar
Recipes 
 
Join Date: Dec 2008
Location: Monmouth County, NJ
Posts: 507
Liked 1 Times on 1 Posts

Default

i use a twisted counterflow copper heat exchanger and I have mashed at 1.25qt/lb. In my case I fill up my mash tun and prime my pump and get it running then I top off at my desired volume. I'm sure I'm a bit thinner on my mash liquor. I find that raising the mash temp in total to a strikeout temp of 168 and then fly sparging for my desired pre boil volume has been stellar.

Good luck, Herms brewing rocks!

__________________
flananuts is offline
 
Reply With Quote Quick reply to this message
Old 03-08-2012, 11:22 PM   #8
milldoggy
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2008
Location: Pottstown, Pa
Posts: 2,038
Liked 62 Times on 51 Posts
Likes Given: 2

Default

Quote:
Originally Posted by flananuts
i use a twisted counterflow copper heat exchanger and I have mashed at 1.25qt/lb. In my case I fill up my mash tun and prime my pump and get it running then I top off at my desired volume. I'm sure I'm a bit thinner on my mash liquor. I find that raising the mash temp in total to a strikeout temp of 168 and then fly sparging for my desired pre boil volume has been stellar.

Good luck, Herms brewing rocks!
Threadjacking here, but do you use a chillzilla to herms? Do you cycle you hlt through the outer part and wort the inner? I have a chillzilla and never thought about using it that way.
__________________
My E-Herms

My hop stopper
milldoggy is offline
 
Reply With Quote Quick reply to this message
Old 03-08-2012, 11:41 PM   #9
BrewinBigD
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Stratham, NH
Posts: 276
Liked 6 Times on 5 Posts

Default

Althoigh a counter flow herms sounds like a great and space saving idea i think youd need alot more insulation to keep all the lines/copper from sinking heat into the air. My systems simple 20ft 5/8 copper coil in my hlt. Its never seen water till tonight actually!

__________________
BrewinBigD is offline
 
Reply With Quote Quick reply to this message
Old 03-09-2012, 08:25 PM   #10
flananuts
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
flananuts's Avatar
Recipes 
 
Join Date: Dec 2008
Location: Monmouth County, NJ
Posts: 507
Liked 1 Times on 1 Posts

Default

Yep, i use a chillzilla as a heat exchanger for heating and cooling exactly as you indicated. I just rigged up valves to switch between my HLT and my house water supply. I don't insulate the coil but my keggles are wrapped in water heater insulation and do work well. I'm very pleased with my eHERMS brewery and the consistency I get.

__________________
flananuts is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
Am I compensating for efficiency correctly? (Beersmith2) phoenixs4r All Grain & Partial Mash Brewing 2 11-23-2011 09:25 PM
Compensating for a low gravity beer with sugar hiphops All Grain & Partial Mash Brewing 2 09-20-2010 08:42 PM
Compensating for boil-off volume JNish All Grain & Partial Mash Brewing 15 08-17-2010 08:17 PM
Fly Sparge - Run Dry or Keep Fluid? Bobby_M All Grain & Partial Mash Brewing 10 04-06-2010 08:24 PM
Compensating for small boil kettle Soperbrew All Grain & Partial Mash Brewing 4 04-10-2008 11:26 PM