jldc 01-04-2009 02:37 PM

New to Kegging - need help
 
I just got a two keg kegerator from Keg Connection.

When trying to set it up, no matter what I do, I can't seem to get any CO2 to flow to the kegs.

The CO2 tank is full, the regulator shows a full tank and is set to 30 PSI.

The gas disconnect is attached to the keg, but nothing flows.

I have tried the stopcocks in all positions, but cannot get the keg to pressurize.

Any help is appreciated. I am getting very frustrated.

EdWort 01-04-2009 02:54 PM

The valve on the regulator will flow when it is inline with the hose going to the keg.

To check, reduce the pressure to 5 psi, remove the gray ball lock and depress the valve on the inside to see if you have flowage. A AA battery works well.

Yooper 01-04-2009 02:55 PM

Did you open the valve at the top of the co2 tank? Is the gas disconnect on the "in" side of the keg?

jldc 01-04-2009 03:04 PM

CO2 tank is open. No flow when pressing valve on the inside of the disconnect.

There is gas to the regulator - It reads pressure and if you close the CO2 tank and take off the regulator there is a hiss of escaping gas. But I can't seem to get any gas to flow to the keg or gas disconnect.

The disconnect is on the "in" side of the keg.

I get the feeling I'm missing something stupid, but I can't figure it out

MoRoToRiUm 01-04-2009 03:26 PM

Do you have an on off switch coming out of the reg on your line? Next step would be taking apart the connect, but I don't see how that could get clogged if it's a new setup..

jldc 01-04-2009 03:30 PM

Quote:

Originally Posted by MoRoToRiUm (Post 1041597)
Do you have an on off switch coming out of the reg on your line? Next step would be taking apart the connect, but I don't see how that could get clogged if it's a new setup..

Not that I can find. I looked for one.

L

EdWort 01-04-2009 04:00 PM

Post a pic of the regulator.

jldc 01-04-2009 04:56 PM

Quote:

Originally Posted by EdWort (Post 1041658)
Post a pic of the regulator.

I can't run my kegerator, but I can post pics on the 'net.

http://i261.photobucket.com/albums/i.../regulator.jpg

http://i261.photobucket.com/albums/i...o/splitter.jpg

BTW the regulator connects to the top right line on the splitter (with the stopcock), not the one at 12 o'clock.

MoRoToRiUm 01-04-2009 05:45 PM

Just to try and isolate the problem; Can you easily SKIP the distribution block and connect a line straight to the corny? If that works have to check the distributor; do you have both feed lines hooked up to a corny that holds pressure? Do you hear any noise or feel movement in any of your lines?

Not quite sure of your quote about where gas in is; personally I would have the gas in going to the one without a switch, and the gas out the ones with a switch. This could be the issue if they have check valves, and you have gas in going to one with a switch. If that is the case, switch it and you should be good!

fifelee 01-04-2009 05:51 PM

I would pull the line off the bottom of the regulator. If no gas comes out then you must have a bad regulator.