The Good...the keezer has been done since early July. It looks awesome and I hope to provide pics asap. I purchased one of kegconnection's premium kits with the tapright setup and perlick faucets.

The Bad...I've gone through 2 5lb tanks since early July. This can't be normal from what I've read from others saying I should be able to go through 5-6+ kegs.

I know when the CO2 tank is within the freezer, the gauge that measures how full it is will drop because of the cooler temps. I have mine set to around 42deg F. I use set and forget and have my stout at about 9 psi and the draught at 12, using the popular chart many of us use.

The first go around things seemed to be holding good for the first few days, then I noticed the level gauge dropped to the lower green section of the full range. I was enjoying my beer for about a month, then one day after being on vacation we came home and all the guages were reading ZILCH (0).

One of my kegs still had pressure, but the other one had none.

So, I talked to Keg Connection. According to their website the kegs are pressure tested, so I cleaned everything and used keg lube the first time withought changing and o'rings, they all looked good. I quickly changed the main lid seal and lubbed it up good, checked tightness of everything else, went and got the tank filled again and pressurized the system again.

I used soapy water and could not find a leak anywhere in the entire system, so I assumed I had fixed the issue with reseating the lid with a new seal.

Jump ahead to a few days ago, and the same dang thing happened. Since it was my Stout keg last time that had no pressure left, I turned that line off. over the next few days it seemed the levels did not drop.

The guages "before" the out lines to the kegs held steady so I think the problem is after the gauges somewhere. I noticed the fitting going into that particular gauge from the stout keg had more threads showing than the other keg so I tightened it up a bit more, but after turning that line back on, tonight the main level gauge was almost 0.

The CO2 tank is about empty as I can easily lift it again.

Sorry for all of this, but I finally had time to post.

I love this hobby, but this is really frustrating me as I have beer I want to drink I can't afford to fill my tank every few months.

Randy

__________________
sirquack is offline
 
Reply With Quote Quick reply to this message
Old 10-06-2010, 02:04 AM   #2
thomashp
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2008
Location: Richmond, VA, Richmond, VA
Posts: 55
Default

The soapy water thing has been hit or miss for me. The easiest way for me to test a keg is to sit up upside down in a bucket of water. The bubbles don't lie.

It could also be an air line leaking. What kind of clamps are you using to tighten down the air hose. Can you tighten those a bit. Make sure the regulator is tight on that bottle as well.

__________________
thomashp is offline
 
Reply With Quote Quick reply to this message
Old 10-06-2010, 02:14 AM   #3
Sea
Green Flash IPA on tap
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Sea's Avatar
Recipes 
 
Join Date: May 2007
Location: Southern Oregon
Posts: 1,477
Liked 5 Times on 5 Posts

Default

Get some leak solution you trust. I use starsan in a spray bottle, but it isn't that great, you'd probably be better off going to your hardware and buying some Gas Leak detector Fluid. Slowly and carefully cover every part of every connection in your system, give the bubbles some time (30-60 seconds) to form. don't forget the less obvious possibilities like the pressure relief valves on your kegs, or the weep hole on your regulator. You'll find the issue with some time and patience.

__________________
I plan on living forever. So far, so good! - unknown.


Corrupt Brewers
Sea is offline
 
Reply With Quote Quick reply to this message
Old 10-06-2010, 02:34 AM   #4
shroomzofdoom
Feedback Score: 0 reviews
Recipes 
 
Join Date: Dec 2009
Location: Piscataway, NJ
Posts: 609
Liked 11 Times on 11 Posts
Likes Given: 6

Default

Also, start by isolating aspects of your system. Use soapy water in a spray bottle or gas leak detector from HW store. Put the tank on the floor, spray the valve. Connect reg, spray. Connect manifold, spray, Connect one hose, spray. Etc etc. Let it sit for 5 minutes each time. I have a manifold with ball valves and these were leaky SOBs. Then when I put it in the freezer it started leaking all over again.

__________________
Mike D

My electric BCS-460 build (work in progress)

Coffin cooling lessons
shroomzofdoom is offline
 
Reply With Quote Quick reply to this message
Old 10-06-2010, 03:38 AM   #5
mozicodo
Feedback Score: 0 reviews
 
mozicodo's Avatar
Recipes 
 
Join Date: Feb 2006
Location: Colorado Springs, CO, CO
Posts: 259
Default

Did you remember the gasket between the CO2 tank and the regulator? I forgot this the first time I hooked up my kegerator many moons ago and had to run out for a refill within a week.

__________________
It may take a real man to brew a big beer, but it takes a big man to brew a real beer.

Xtreme Mashtun Build Open Beer Data Project @aptidude on identi.ca

Android Software: ZymTools Free ZymTools Full
mozicodo is offline
 
Reply With Quote Quick reply to this message
Old 10-06-2010, 11:39 PM   #6
sirquack
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2010
Location: Iowa
Posts: 30
Default

I have determined that the leak has to be "after" the 2 gauge regulator assembly, as if I turn off the independent lines feeding each keg the pressure holds. Also, since one of the kegs seems to hold pressure, it has to be just the stout keg. Everything is pre-assembled by Keg Connection in the premium kit, to answer your question Thomas.

The last time I mixe up a very dish soap solution and coated every single possible location on the kegs, fittings, and lines, and inspected very closely. Since I was unable to locate any bubbles, I assumed adding a new lid seal resolved the issues, I was wrong..

Their Tapright assemblies have a built in rubber seal that goes into the CO2 tank, your not suppose to use other seals in combination with this type.

thanks guys, I will have to keep looking and try to find this leak solution you speak up from the local stores....

__________________
sirquack is offline
 
Reply With Quote Quick reply to this message
Old 10-07-2010, 01:02 AM   #7
Mayday99
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2007
Posts: 154
Liked 1 Times on 1 Posts
Likes Given: 2

Default

Did you change all the o-rings on the kegs?

__________________
Mayday99 is offline
 
Reply With Quote Quick reply to this message
Old 10-07-2010, 01:06 AM   #8
sirquack
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2010
Location: Iowa
Posts: 30
Default

I think I mentioned above in my novel, , all the o-rings looked to be in very good condition, and Keg Connection pressure tests everything before shipping. I did use keg lube on all of them. After the first leak, I did replace the main lid o'ring on the keg I think is causing the problem.

__________________
sirquack is offline
 
Reply With Quote Quick reply to this message
Old 10-07-2010, 01:09 AM   #9
ArcaneXor
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2007
Posts: 4,410
Liked 74 Times on 70 Posts
Likes Given: 14

Default

"Set it and forget it" is dangerous when you have a leak. I suggest doing the upside-down-keg leak check, as well as submerging the gas line to gas quick disconnect connection to make sure that you don't (I had a leak there once because the connection loosened from switching between kegs a lot).

__________________
The Fiesty(sic) Goat Brewery est. 2007 & Clusterfuggle Experimental Ales est. 2009
Primary: Saison, Berliner Weisse, sLambic I, sLambic II, IPA, 70/-
Secondary: Orange Blossom Mead, Flanders Red I
Kegged: Fat Man Porter w/ 1469, Fat Man Porter w/ 005, Centennial Falcon w/ Conan, Centennial Falcon w/ Denny's, Barrel-aged Fat Man Porter, Belgian Dark Strong, Dark Mild
ArcaneXor is offline
 
Reply With Quote Quick reply to this message
Old 10-07-2010, 01:17 AM   #10
sirquack
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2010
Location: Iowa
Posts: 30
Default

So with beer in the kegs and preasurized, turn them so the top end is submerged? One question is how long with my beer last before I can go run and get the tank refilled. My draught is ok as that keg is holding the CO2, but the stout has no preasure. Thanks for all the help. I suppose I could go ahead and swap out all the orings, just hate to expose my good beer to the air outside. I might wait until that keg is empty.

__________________
sirquack is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
Happy Keezer day! Loup Bottling/Kegging 20 11-03-2010 03:21 AM
Air leaks from keg below 10 psi TXhophead Bottling/Kegging 13 03-02-2009 01:57 AM
Possible leaks and what to do? Roman Brewer Bottling/Kegging 6 07-10-2008 06:07 PM
Lid leaks on new keg Hillbillie PHiL Bottling/Kegging 13 12-21-2007 03:48 PM
Air Leaks. bs22619 Bottling/Kegging 8 12-19-2007 04:34 PM