Default Danby dkc645bls Not Cooling

Hey everyone, looks like I have some cooling issue with my kegerator. I went to grab a beer last night and noticed it said 53 degrees (usually 43). The compressor was running and wasn't hot, so figured maybe it just kicked in late (stupid Danby thermostats). But then about an hour later, I noticed it was still at 53 degrees, with the compressor still running, but now hot. I put a fan on the compressor so it didn't overheat, but 30 min later...still 53. So now I take out the keg and make sure the coils are cold...they aren't. I noticed some ice build up so unplugged the fridge and let it sit overnight open. In the morning, there was a little water in the rear drain catch, but not much. I unscrewed the rear coils and pulled it out, then turned on the fridge. The inlet to the coils (small copper pipe) gets really cold and even frosts over, but the coil plate never gets cold. Also, the return (bigger copper pipe) is not getting cold, either. I do hear a slight hissing/running fluid when the compressor is running, which btw itself is not making any weird noises and sounds healthy. Any ideas? Below is a link to a couple of pictures.

Keg Pics

In the first picture you can see the frosted over inlet on the left. The second picture is the cooling plate that is currently warm.

Thanks for reading and any advice is appreciated!



__________________
vwjet2001 is offline
 
Reply With Quote Quick reply to this message
Old 08-13-2012, 07:29 PM   #2
vwjet2001
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2012
Location: Omaha, NE
Posts: 3
Default

Thought I would follow up for anyone that finds this thread and has the same issue. Turns out it was low on charge and needed some R134a. Did this by putting an R12 self tap into the line (can be done without losing freon) and then using an R12 to R134a adapter (auto parts store). Then fill to 130 PSI with the compressor running and warm using a car recharge kit. Worked for me and still cooling fine. The adapter and tap were around 15 bucks, so definitely worth the attempt to fix it.

__________________
vwjet2001 is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools
Display Modes


Similar Threads
Thread Thread Starter Forum Replies Last Post
Danby dkc645bls Not Cooling vwjet2001 Bottling/Kegging 0 07-30-2012 09:44 PM
Question for Danby DKC645BLS owners zman Bottling/Kegging 9 01-07-2012 05:58 PM
Modifying a Danby DKC645BLS for a 2 or 3 tap tower zman Bottling/Kegging 10 01-19-2011 06:22 AM
Danby 4.4 cu. ft. big enough for 2? Brewme Bottling/Kegging 9 01-06-2009 02:52 AM
Danby DKC645BLS experience? jelsas Bottling/Kegging 3 07-31-2007 02:19 PM