Ok I know I am probably beating a dead horse here with the whole propane manifold question but, I have no idea really what parts I will need to build a manifold for a 3 tier tree style brewing stand. I plan on using black pipe for the tubing and teflon tape and pipe dope on all the connections and 3 ball valves rated for propane gas use. I am using 3 bayou classic burners(yeah I know, I should get banjos but, swmbo controls the pocket book)I just want to know what kind of fittings and hose assemblys to get to make it work safe. Any information or tips would be great! Cheers!

__________________
whiteheadcraftbeers is offline
 
Reply With Quote Quick reply to this message
Old 06-14-2012, 10:18 PM   #2
carlisle_bob
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2012
Location: Carlisle, PA
Posts: 1,205
Liked 27 Times on 26 Posts

Default

Hi

The black pipe is your manifold in this case. The tee's and pipe sections are what create the manifold. Put another way:

Each valve pairs with the middle of a tee. The outside arms of the tee go to chunks of the middle tee go to chunks of pipe. Both of those chunks to to the other tee's (and valves). A plug goes in the top tee. Your supply line goes in the bottom tee.

After the ball valves you will need tubing to get to the needle valves that control flow to the burners. Exactly what sort depends on weather you are setting up for low pressure (< 0.5 psi) or high pressure (up to 30 psi) propane. Which will you be running?

Bob

__________________
carlisle_bob is offline
 
Reply With Quote Quick reply to this message
Old 06-14-2012, 11:58 PM   #3
whiteheadcraftbeers
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2012
Location: Toledo, OH
Posts: 22
Default

Bob, I plan on going with high pressure. I guess I am confused, I will need ball valves and needle valves or just needle valves. I guess I thought you just had to go propane tank hose to bottom of manifold then a length of pipe to first tier, use a tee then a ball valve and another length of pipe then hose to connect from manifold to burner, then repeat for each tier and use a pipe cap at the top to close it off. I guess maybe I'm more confused then I thought. Thanks again!

Tim

__________________
whiteheadcraftbeers is offline
 
Reply With Quote Quick reply to this message
Old 06-15-2012, 01:21 AM   #4
carlisle_bob
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2012
Location: Carlisle, PA
Posts: 1,205
Liked 27 Times on 26 Posts

Default

Hi

You can go with needle valves and no ball valves, but not with ball valves and no needle valves. The "primo" way to go is ball (or gate) valves and needle valves. That way you can set the needle to have the right flame level and just use the other valve to turn things on and off.

If you are running high pressure, be sure you are running tube that's rated for 30 psi. Tubing (copper or aluminum) is a good choice. There are several other choices.

Will you be running pilot lights (highly recommended)? if so they need their own feed....

Will you be running ignitors (also highly recommended)? If so they need electric valves.

Bob

__________________
carlisle_bob is offline
 
Reply With Quote Quick reply to this message
Old 06-15-2012, 01:34 AM   #5
Patirck
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2010
Location: Glendale, CA
Posts: 750
Liked 12 Times on 12 Posts
Likes Given: 1

Default

High pressure is fine unless you want to add automation - the honeywell valves and like use low pressure. You can use low pressure without automation as well. Low versus High pressure is determined by the regulator on the propane bottle.

__________________
Patirck is offline
 
Reply With Quote Quick reply to this message
Old 06-15-2012, 02:42 AM   #6
whiteheadcraftbeers
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2012
Location: Toledo, OH
Posts: 22
Default

Bob, at this point I will not be running pilot lights or ignitors, just want to keep it cheep yet safe and functional. Ok with this knowledge in hand what are the list of the rest of the fittings I will need to get this done right?

Patrick, I'm using a 0-40PSI regulator.

Thanks again!

Tim

__________________
whiteheadcraftbeers is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
My new 3 tier stand eknee Brew Stands 37 03-13-2012 10:30 PM
Propane Manifold is to big cdelap Brew Stands 2 02-21-2012 08:59 PM
What 3-tier stand configuration is best? FirstStateBrewer Brew Stands 9 02-03-2012 06:51 PM
Propane Manifold for Brew Stand Question DrewC Brew Stands 2 11-26-2011 02:03 PM
Need 3 tier brew stand MikeBrnDmgd Brew Stands 1 11-19-2011 11:22 PM



Newest Threads

LATEST SPONSOR DEALS