Default Electrical Help with Control Panel for Electric Kettle

I plan on wiring a control panel to control a 4500w kettle. I also have a 15 amp outlet for my pump, although I do not need any kind of control for it (maybe just a switch). I tried to piece together a diagram based on numerous posts I have read here (apologies for the crudeness of the diagram). I was curious if some of you electrical pros could take a look and provide comments/suggestions. I also have a few questions for you.



1. If I wanted to completely kill the element while still letting the PID monitor temperature, where should the kill switch be located?

2. Where would the neutral wire go for the element? Or is it not necessary?

3. I have fuses before the PID. Should I put them before the SSRs on the lines that do not go to the PID?

4. The locking plugs/receptacles, what are the advantages/disadvantages of those? I notice a lot of guys around here use them and was curious as to the reason.

5. For the actual box itself, metal or plastic?

Thanks in advance.

__________________
TheAleMaster is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 01:25 AM   #2
The Pol
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2007
Posts: 11,774
Liked 75 Times on 64 Posts
Likes Given: 14

Default

You dont need a switch, you have 2 SSRs....?

No neutral on 240VAC

I think fusing the PID is all you really need, unless you are trying to protect the elements?

Locking receptacles are good if you are worried about them coming unplugged. FWIW I almost need a pry bar to get my 4 prong plug out of the 50A receptacle as it is.

Box material is up to you... both are suitable. I prefered plastic (insulator)

__________________
The Pol is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 01:58 AM   #3
CodeRage
Death by Magumba!
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
CodeRage's Avatar
Recipes 
 
Join Date: Aug 2007
Location: Melbourne, Fl
Posts: 2,254
Liked 33 Times on 18 Posts
Likes Given: 5

Default

Quote:
Originally Posted by TheAleMaster View Post
I plan on wiring a control panel to control a 4500w kettle. I also have a 15 amp outlet for my pump, although I do not need any kind of control for it (maybe just a switch). I tried to piece together a diagram based on numerous posts I have read here (apologies for the crudeness of the diagram). I was curious if some of you electrical pros could take a look and provide comments/suggestions. I also have a few questions for you.

1. If I wanted to completely kill the element while still letting the PID monitor temperature, where should the kill switch be located?
The best solution would be a 2 pole contactor switching L1 and L2 before it goes into the SSR. contactor

2. Where would the neutral wire go for the element? Or is it not necessary?
Not needed

3. I have fuses before the PID. Should I put them before the SSRs on the lines that do not go to the PID?
Nah

4. The locking plugs/receptacles, what are the advantages/disadvantages of those? I notice a lot of guys around here use them and was curious as to the reason.
Nice to know that the plug is locked into place. Just in case the cord gets tugged on or what not. Nothing mandatory though

5. For the actual box itself, metal or plastic?
no plastic. Should use metal or fiberglass. Should there be a fire, fiberglass is self extinguishing, not sure about the plastic. I prefer metal. Make sure it is good and grounded so if a wire comes loose and hits it, it will pop the breaker. But fiberglass is just as acceptable.

Thanks in advance.
No problem, sorry I didn't get back to your PM though. I saw it at work and was going to respond later but forgot .
__________________
Brutus 20e build | Electrical Primer for Brewers | Auber SYL-2362A2 PID Install & Config
So as I am walking out the door this morning I think to my self:
"self, going to work on Monday is like knowing you're going to get kicked in the nuts. You just don't know when or by who"

Reason: grammar bad much many
CodeRage is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:01 AM   #4
The Pol
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2007
Posts: 11,774
Liked 75 Times on 64 Posts
Likes Given: 14

Default

Do you need a switch if you have 2 SSRs? Can the PID be the switch?

__________________

The Pol is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:06 AM   #5
CodeRage
Death by Magumba!
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
CodeRage's Avatar
Recipes 
 
Join Date: Aug 2007
Location: Melbourne, Fl
Posts: 2,254
Liked 33 Times on 18 Posts
Likes Given: 5

Default

Quote:
Originally Posted by The Pol View Post
Do you need a switch if you have 2 SSRs? Can the PID be the switch?
it can, I feel better with a mechanical disconnect over a piece of silicone.
__________________
Brutus 20e build | Electrical Primer for Brewers | Auber SYL-2362A2 PID Install & Config
So as I am walking out the door this morning I think to my self:
"self, going to work on Monday is like knowing you're going to get kicked in the nuts. You just don't know when or by who"
CodeRage is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:16 AM   #6
egurney
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2008
Posts: 262
Liked 1 Times on 1 Posts

Default

CodeRage,
you said

Quote:
5. For the actual box itself, metal or plastic?
no plastic, metal of fiberglass.
Did you mean?
No plastic. Metal or Fiberglass is good.
__________________
egurney is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:17 AM   #7
CodeRage
Death by Magumba!
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
CodeRage's Avatar
Recipes 
 
Join Date: Aug 2007
Location: Melbourne, Fl
Posts: 2,254
Liked 33 Times on 18 Posts
Likes Given: 5

Default

Quote:
Originally Posted by egurney View Post
CodeRage,
you said

Did you mean?
No plastic. Metal or Fiberglass is good.
Ha, yeah
Plastic Baaaaaaad
Metal & Fiberglass Gooooooood
__________________
Brutus 20e build | Electrical Primer for Brewers | Auber SYL-2362A2 PID Install & Config
So as I am walking out the door this morning I think to my self:
"self, going to work on Monday is like knowing you're going to get kicked in the nuts. You just don't know when or by who"
CodeRage is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:18 AM   #8
The Pol
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2007
Posts: 11,774
Liked 75 Times on 64 Posts
Likes Given: 14

Default

My whole electric rig is wood, I am screwed

Dont they make junction boxes, NEMA boxes, out of plastic??

__________________
The Pol is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:20 AM   #9
CodeRage
Death by Magumba!
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
CodeRage's Avatar
Recipes 
 
Join Date: Aug 2007
Location: Melbourne, Fl
Posts: 2,254
Liked 33 Times on 18 Posts
Likes Given: 5

Default

Quote:
Originally Posted by The Pol View Post
My whole electric rig is wood, I am screwed

Dont they make junction boxes, NEMA boxes, out of plastic??
Lol, just keep a fire extinguisher handy. Remember, kill power, then spray.

Edit. They do, but when you say plastic that means it could be anything; a radio shack project box or your scooby doo lunch box.
__________________
Brutus 20e build | Electrical Primer for Brewers | Auber SYL-2362A2 PID Install & Config
So as I am walking out the door this morning I think to my self:
"self, going to work on Monday is like knowing you're going to get kicked in the nuts. You just don't know when or by who"
CodeRage is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2010, 02:21 AM   #10
The Pol
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2007
Posts: 11,774
Liked 75 Times on 64 Posts
Likes Given: 14

Default

Quote:
Originally Posted by CodeRage View Post
Lol, just keep a fire extinguisher handy. Remember, kill power, then spray.
I will get dry chem.
__________________
The Pol is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
Control Panel airbalancer Brew Stands 68 04-16-2010 09:22 PM
New Control Panel p-nut Brew Stands 16 01-26-2010 12:41 PM
Thermostat control for Electric HLT or Kettle Boodlemania Equipment/Sanitation 1 03-21-2009 11:59 AM
Electric kettle with PID control neo82087 Brew Stands 62 11-28-2008 01:35 PM
My control panel Brewpastor Brew Stands 7 03-14-2007 10:05 PM



Newest Threads

LATEST SPONSOR DEALS