A reader suggested that I document this work in its own thread (part of it appears in another thread). Here it goes.

This thread is to document an approach to a RIMS or eHERMS heating element which can be used with insulated vessels to maintain and adjust temperatures for mashes for 5 to 10 gallon batches.

I have been using two of these elements with 2+ hour mash schedules from dough in to mash out under PID control for 5 and ten gallon batches with reasonable, repeatable results.

NOTES:

Always use GFI circuits.
Always verify flow through the pipe

Design Goals
1) Use easy to obtain parts (McMaster Carr for example)
2) Safe to use on 110V 20Amp Circuit (16amp budget)
3) Easy to clean, no internal heating elements does not require dis-assembly to clean
4) Modular, can add additional watts as required (subject to the amperage limits)
Back of the envelope calculation
The 8ft 624 Watt 120VAC Extreme-Temperature heat tape requires 5.2 Amps. If the system uses two of these heaters + a PID (budget 1 Amp), plus a March pump (budget 1.5Amps) We get approx 13Amps, which is less than 80% of a 20 Amp Circuit.
Parts [McMaster Carr is one source]
1) Extreme-Temperature Heat Cable 13 Watts/Square Inch, 8 ft Length, 624 Watts, 120 V, :: make sure that the tape can be used over metal. See Laboratory Electric Heating Elements Tapes Heating Jackets Heating Blankets Insulated Resistant Wire for precautions.
2) Ultra-High Temp Foil-Faced Insulation Strip 1/2" Thick, 3" X 12', :: make sure that the insulation can withstand direct contact with the heating element. Fiberglass is NOT okay to use.
3) 18” of ½ stainless steel pipe threaded both ends
4) (2) ½ inch stainless steel Female Pipe Tees
5) (2) ½ inch stainless steel Square Head Plugs
If there is interest I will take photos on the new build as the parts come in.

As always, safety first.
__________________

Reason: typo
rosienej is offline
 
Reply With Quote Quick reply to this message
Old 01-11-2012, 05:58 PM   #2
audger
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2011
Location: ., Connecticut
Posts: 1,497
Liked 40 Times on 40 Posts
Likes Given: 1

Default

ive never seen someone try to heat the mash tun using tape. neat idea. i might keep that in mind for when i redesign my HERMS tank/mash tun setup eventually.

__________________
audger is offline
 
Reply With Quote Quick reply to this message
Old 01-11-2012, 06:42 PM   #3
Huaco
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
Huaco's Avatar
Recipes 
 
Join Date: Dec 2011
Location: Just south of Cow Town, Tx
Posts: 1,243
Liked 114 Times on 71 Posts
Likes Given: 34

Default

Ummm... YES! I would LOVE to follow this build. I have not made up my mind on HERMS or RIMS yet and I am interested in seeing this option. I am just not too keen on the idea of a heating element confined in a make-shift tube that has to be sealed up with thinned down JB weld. This, otoh, is external heating...

__________________
Huaco is offline
 
Reply With Quote Quick reply to this message
Old 01-11-2012, 07:18 PM   #4
rosienej
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Colchester, CT
Posts: 160
Liked 2 Times on 2 Posts
Likes Given: 1

Default

Just put in an order.
1) I didn't purchase the insulation (I have some left over from the last build)
2) I picked up a 3 inch threaded pipe to connect the systems.

------------------------------------------ McMaster -----------------------------

1 1 each 4550T141 Extreme-Temperature Heat Cable 13 Watts/Square Inch, 8 ft Length, 624 Watts, 120 V today $73.46 each 73.46
2 2 each 4452K434 Type 316 Stainless STL Threaded Pipe Fitting 1/2 Pipe Size, Tee, 150 PSI today $10.31 each 20.62
3 2 each 4452K124 Type 316 Stainless STL Threaded Pipe Fitting 1/2 Pipe Size, Square Head Plug, 150 PSI today $4.28 each 8.56
4 1 each 4816K124 Standard-Wall Type 316/316L SS Threaded Pipe 1/2 Pipe Size X 18" Length today $23.89 each 23.89
5 1 each 4548K175 Std-Wall Type 316/316L SS Thrd Pipe Nipple 1/2 Pipe Size X 3" Length today $5.37 each 5.37
__________________
rosienej is offline
 
Reply With Quote Quick reply to this message
Old 01-11-2012, 08:28 PM   #5
Huaco
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
Huaco's Avatar
Recipes 
 
Join Date: Dec 2011
Location: Just south of Cow Town, Tx
Posts: 1,243
Liked 114 Times on 71 Posts
Likes Given: 34

Default

What kind of insulation are you going to use?

__________________
Huaco is offline
 
Reply With Quote Quick reply to this message
Old 01-11-2012, 08:47 PM   #6
rosienej
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Colchester, CT
Posts: 160
Liked 2 Times on 2 Posts
Likes Given: 1

Default 2100 degree F Max

Quote:
Originally Posted by Huaco View Post
What kind of insulation are you going to use?
http://www.mcmaster.com/#9379K93

The pipe heaters max temp output is 1400 degrees F so there is a bit of a margin.

I purchased two rolls last year, One roll is enough for two heaters.
__________________
rosienej is offline
shoshin Likes This 
Reply With Quote Quick reply to this message
Old 01-11-2012, 08:56 PM   #7
rosienej
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Colchester, CT
Posts: 160
Liked 2 Times on 2 Posts
Likes Given: 1

Default One More Safety Feature.

Once I build my heater, I will be mounting the pair in a box, to make the setup a little nicer. To prevent overheating, I will put in series one the following thermal fuse on each heater, outside of the insulation.

THERMAL FUSE 128C 10A AXIAL - SDF DF128S

These are one shot use, but for less than 1 buck each, we can keep the setup from safe if we loose flow and don't notice.

Joel

__________________
rosienej is offline
 
Reply With Quote Quick reply to this message
Old 01-12-2012, 05:48 AM   #8
SmokingDog
Feedback Score: 1 reviews
Recipes 
 
Join Date: Feb 2011
Location: Sheboygan, WI
Posts: 126
Liked 2 Times on 2 Posts

Default

So essentially an ERIMS (external RIMS) tube? Seems very simple, eliminates scorching.
Will it heat enough depending on the flow of wort?
Also, putting the heating tubes in a box, seems like adding heat to heat in an enclosed area.

Just thoughts. But very interested.

__________________
SmokingDog is offline
 
Reply With Quote Quick reply to this message
Old 01-12-2012, 01:01 PM   #9
rosienej
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Colchester, CT
Posts: 160
Liked 2 Times on 2 Posts
Likes Given: 1

Default

Quote:
Originally Posted by JonesCreek View Post
So essentially an ERIMS (external RIMS) tube? Seems very simple, eliminates scorching.
Will it heat enough depending on the flow of wort?
Also, putting the heating tubes in a box, seems like adding heat to heat in an enclosed area.

Just thoughts. But very interested.
I have been using it with 2+ hour mash schedules for mashes of 5 and 10 gallon batches. From dough in to mash out largely unattended. It works well.

The current system uses two different types of heat tape for a total of 1024 Watts, one test showed the system can raise 5 gallons of water (insulated Gott cooler and pipes, constant circulation) approx 1 degree every 6 minutes. It does depend on ambient temp etc.

I am upping the wattage a bit with the new build, and the new system with two elements will have 1248 Watts.

I think, having more insulation the better. Installing in the enclosed box with the clean-outs on the ends of the heating pipes exposed should improve the performance. Of course I need the thermal fuses to keep everything safe if flow is stopped, or the heater is left on by mistake.

I found the following site to be helpful. Calculating Heat Loss - Features - Process Heating

Thanks for the interest. I will be posting pictures of the build process as the parts come in.

Joel
__________________
rosienej is offline
 
Reply With Quote Quick reply to this message
Old 01-12-2012, 02:52 PM   #10
thelorax121
Feedback Score: 0 reviews
Recipes 
 
Join Date: Apr 2009
Location: Athens GA
Posts: 419
Liked 1 Times on 1 Posts
Likes Given: 1

Default

Sounds good, I have been contemplating an ERIMS for a while myself using heating tape. Any chance you could post some pics when you finish the build?

__________________
thelorax121 is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
electric heating element Brewpastor Brew Stands 9 01-01-2012 10:20 PM
Burned out Heating Element - RIMS JVD_X Brew Stands 47 09-09-2010 12:22 AM
Electric Heating Element noblanks1969 Brew Stands 5 04-25-2010 04:57 PM
anyone consider installing an electric heating element to their BK? krausenmustache Kettles, Mash Tuns, & Hot Liquor Tanks 24 05-12-2009 06:29 PM
No-welding electric heating element? RockfordWhite Brew Stands 4 12-27-2007 06:52 AM



Newest Threads

LATEST SPONSOR DEALS