Default 24V to 5V step down

Ok so I got my 24V AC/DC transformer for my gas valves and would like to use it for my SSR's (pumps) as well for the manual turn on. I'm going to run the 5Vdc from BCS for the auto turn on.(using a three way switch). Problem I am having is the only step down I can find I have to get from Hong Kong. I know some one hear has a good place to shop for this. What are you guys using Im thinking about 100W so if need be I can add to system.
Thanks,
Ryan

__________________
Brewn4life is offline
 
Reply With Quote Quick reply to this message
Old 02-13-2013, 03:57 AM   #2
passedpawn
Waste Allocation Load Lifter - Earth Class
HBT_MODERATOR.png
Feedback Score: 0 reviews
 
passedpawn's Avatar
Recipes 
 
Join Date: Apr 2009
Location: ☼ Clearwater, FL ☼
Posts: 19,433
Liked 3513 Times on 2170 Posts
Likes Given: 3013

Default

You are looking for 120VAC in, 24VDC out?

Or 24VDC in, 5VDC out?

I'm not following

__________________
Hey goomba I love how you dance the rumba
But take some advice paisano learn-a how to mambo
If you're gonna be a square you ain't-a gonna go anywhere.
passedpawn is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 02:01 AM   #3
Brewn4life
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2011
Location: LosAngeles, Ca
Posts: 102
Liked 1 Times on 1 Posts

Default

24Vdc to 5Vdc, but Im thinking the SSR's have a 3-32Vdc trigger any ways.
https://www.oscsys.com/store/product/272
So what the hell I could just get a 3 way switch that can handle 24Vdc which would be my manual on(pump) and BCS could handle the auto on/off. One transformer powering the pumps and gas valves. All different relays of course.

Oh and I have the transformer to go from 120Vac to 24Vdc

__________________
Brewn4life is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 02:17 AM   #4
Brewn4life
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2011
Location: LosAngeles, Ca
Posts: 102
Liked 1 Times on 1 Posts

Default

Actually upon further evaluation my transformer is actually a 110Vac to 24Vac...back to square one.....finding a control voltage source for the manual on of the SSR's

__________________
Brewn4life is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 03:47 AM   #5
alien
Feedback Score: 1 reviews
Recipes 
 
Join Date: Apr 2012
Location: Philadelphia, PA
Posts: 1,235
Liked 65 Times on 58 Posts
Likes Given: 61

Default

Put the 24VAC through bridge rectifier then connect the output through a big capacitor (like 1000 uF / 50V) to ground. The output will be about 30VDC which should be OK for the SSR input.

alien is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 10:41 AM   #6
Maxkling
Feedback Score: 0 reviews
Recipes 
 
Join Date: Oct 2010
Location: Atlanta, Georgia
Posts: 497
Liked 9 Times on 7 Posts

Default

Why not just use a wall wart or some form of power supply?

__________________

"It’s so simple to be wise. Just think of something stupid to say and then don’t say it."

"Gun Control Means Using Both Hands."

Maxkling is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 11:00 AM   #7
cooldood
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2013
Location: Belgrade, Maine
Posts: 548
Liked 117 Times on 90 Posts
Likes Given: 38

Default

Doorbell power supply is all you need

very cheap

__________________
cooldood is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 12:16 PM   #8
passedpawn
Waste Allocation Load Lifter - Earth Class
HBT_MODERATOR.png
Feedback Score: 0 reviews
 
passedpawn's Avatar
Recipes 
 
Join Date: Apr 2009
Location: ☼ Clearwater, FL ☼
Posts: 19,433
Liked 3513 Times on 2170 Posts
Likes Given: 3013

Default

Quote:
Originally Posted by alien View Post
Put the 24VAC through bridge rectifier then connect the output through a big capacitor (like 1000 uF / 50V) to ground. The output will be about 30VDC which should be OK for the SSR input.
Actually, an unloaded 24VAC transformer will probably get you 28VAC, and rectified / filtered will end up 38-39 VDC. Depends on the current rating of the transformer.
__________________
Hey goomba I love how you dance the rumba
But take some advice paisano learn-a how to mambo
If you're gonna be a square you ain't-a gonna go anywhere.
passedpawn is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 12:18 PM   #9
passedpawn
Waste Allocation Load Lifter - Earth Class
HBT_MODERATOR.png
Feedback Score: 0 reviews
 
passedpawn's Avatar
Recipes 
 
Join Date: Apr 2009
Location: ☼ Clearwater, FL ☼
Posts: 19,433
Liked 3513 Times on 2170 Posts
Likes Given: 3013

Default

Quote:
Originally Posted by Maxkling View Post
Why not just use a wall wart or some form of power supply?
That's what I would do, too.
__________________
Hey goomba I love how you dance the rumba
But take some advice paisano learn-a how to mambo
If you're gonna be a square you ain't-a gonna go anywhere.
passedpawn is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2013, 12:25 PM   #10
Brewn4life
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2011
Location: LosAngeles, Ca
Posts: 102
Liked 1 Times on 1 Posts

Default

Cool was looking at the Power supply's and that will work. All the Doorbell power supply's were AC out put so I m not sure which ones your talking about. Send a link please. I did not get a chance to look at the Bridge Rectifier yet will do after work. Thanks for your help.

__________________
Brewn4life is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
XXXXX's Whirlpool WAR349BSL Kegerator Conversion (37 picture step-by-step slideshow) XXXXX DIY Projects 32 08-24-2014 04:21 PM
Step-by-step: Using amylase to convert flaked corn jsweet Gluten Free Brewing 12 03-10-2012 08:27 AM
5/8" OD Immersion Chiller, a Visual Step by Step PowderedToast DIY Projects 11 12-13-2011 11:37 PM
Mashing Oats - Proper Temperature (2 step or single step) tmm0f5 Beginners Beer Brewing Forum 4 11-23-2011 07:46 PM
Making a yeast starter - Step by Step Video johnnyc Fermentation & Yeast 2 02-05-2010 07:52 PM