I've tried searching for this, but haven't found anything that definitively (for me, at least) answers the question.

I'm planning on using a 12" x 12" x 6" plastic junction box. I've got 2 40A SSR's and heatsinks from Auber, which will send power to each leg of a 4500W ULWD element. This element will be used in a combination MLT/BK, for mash heating and boiling.

The SSR's will reside in the control box with a row of 5 DIN-rail circuit breakers (one a double pole), a row of DIN-rail terminal blocks, and the back side of an Auber PID, 5 SPST switches, a 220V outlet, and 4 110V outlets.

I understand that putting the heatsinks on the outside of the box (by mounting the SSR's and heat sinks to opposite sides of an aluminum plate with silicone grease, which is mounted in a hole in the plastic box) is the technically ideal method. However, I'd really like to keep everything within the box itself, mostly due to space concerns (and, to a lesser extent, aesthetics).

Any and all suggestions are welcome. Thanks!

__________________
Patched Kettle Brewery

"Drilling more holes than we need to, since 2010."
ExHempKnight is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 04:13 PM   #2
SOB
Feedback Score: 0 reviews
Recipes 
 
Join Date: Dec 2006
Location: Delaware, OH
Posts: 975
Liked 5 Times on 5 Posts

Default

How tall is the SSR\Heatsink combo? Will it fit? I would also be worried about the heat. You may need some air movement in the box.

__________________
"So we were slammin' beers in the church parking lot..."

"I'm much too young to feel this damn old"
SOB is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 04:25 PM   #3
jkarp
Beer Herder
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
jkarp's Avatar
Recipes 
 
Join Date: Jun 2008
Location: Elizabeth, CO
Posts: 2,105
Liked 33 Times on 29 Posts
Likes Given: 4

Default

Mounting the heatsinks inside is no problem but you'll need ventilation to draw the heat out.

__________________
jkarp is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 06:25 PM   #4
Hermit
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2009
Location: Alternate Universe
Posts: 2,231
Liked 61 Times on 55 Posts
Likes Given: 10

Default

My understanding is that they heat up when switching. The faster they switch, the more heat they give off. I'd second the suggestion of a fan to force ventilation probably. Heat kills electronic components.

__________________
Hermit is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 06:49 PM   #5
Sawdustguy
Feedback Score: 1 reviews
Recipes 
 
Join Date: Mar 2009
Location: Manorville, New York
Posts: 2,772
Liked 28 Times on 25 Posts

Default

Quote:
Originally Posted by Hermit View Post
My understanding is that they heat up when switching. The faster they switch, the more heat they give off. I'd second the suggestion of a fan to force ventilation probably. Heat kills electronic components.

+1 If you mount it in the box with no holes for ventilation or no forced cooling via a fan, don't blame us when something inside the box fails due to heat stress.
__________________

Guy

Sawdustguy is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 06:55 PM   #6
TheFlyingBeer
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2007
Location: Catonsville, MD
Posts: 425
Liked 13 Times on 12 Posts
Likes Given: 3

Default

They will heatup when in a steady on state because the internal components create a small voltage drop on the load side and some of that is wasted as heat. As previously stated the heat generation is proportional to the current passing through the SSR.

__________________

Primaries: Air
Secondaries: Lakefront India Brown Ale

On Tap 1: Rootbeer, On Tap 2: NB White ouse Honey Ale, On Tap 3: Nitrogen, On Tap 4: Air, On Tap 5: Air
On Deck: DIPA, Imp Stout, Porter, Wheat, Black IPA

"No sense having empty carboys around when full ones take up just as much space. " - Me
TheFlyingBeer is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 07:01 PM   #7
samc
Feedback Score: 1 reviews
Recipes 
 
Join Date: Aug 2008
Location: Portland OR
Posts: 5,420
Liked 54 Times on 51 Posts
Likes Given: 29

Default

Mounting them outside of the box will free up a lot of space. Seems like a big box until you start filling it up with stuff. Buy the size box you think you need then add 30-50% more space for future use and ease of working inside.

__________________
samc is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 09:51 PM   #8
ExHempKnight
Feedback Score: 0 reviews
Recipes 
 
Join Date: Oct 2010
Location: Roanoke
Posts: 117
Liked 2 Times on 2 Posts

Default

I thought as much. Like I said, I know that the proper way is mounting the heat sinks externally. I was just curious if anyone had mounted them internally without issue.

__________________
Patched Kettle Brewery

"Drilling more holes than we need to, since 2010."
ExHempKnight is offline
 
Reply With Quote Quick reply to this message
Old 02-14-2011, 10:38 PM   #9
Hermit
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2009
Location: Alternate Universe
Posts: 2,231
Liked 61 Times on 55 Posts
Likes Given: 10

Default

Let's not confuse the issue to much but external doesn't have to be the right way of doing it. Enclosed with forced circulation may well be better if done properly. It is about air movement across the heat sync. Just because it is out of the box doesn't mean you will get better air movement. Well, it does if you don't ventilate the box.

__________________
Hermit is offline
 
Reply With Quote Quick reply to this message
Old 02-15-2011, 04:33 AM   #10
ExHempKnight
Feedback Score: 0 reviews
Recipes 
 
Join Date: Oct 2010
Location: Roanoke
Posts: 117
Liked 2 Times on 2 Posts

Default

I agree that internal heat sinks with forced-air ventilation would be fine, but drilling holes for said ventilation would negate any water-resistance-ness, which is of a higher priority than looks.

I think I'll just cut the topmost plate off the heat sinks (opposite the SSR end), mount them on the outside, and call it a day.

__________________
Patched Kettle Brewery

"Drilling more holes than we need to, since 2010."
ExHempKnight is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
My new Control Box... Dgonza9 Electric Brewing 19 11-09-2012 03:00 PM
Control Panel VS Computer Bru Electric Brewing 14 01-26-2012 01:35 AM
Need inside nut for heatstick in kettle beeguy Electric Brewing 10 05-20-2011 11:34 PM
Do I need a heatsink? Dgonza9 Electric Brewing 6 11-06-2010 06:33 PM
need input on control panel SpaceCoastBrew Electric Brewing 13 10-28-2010 02:28 PM