Get your HBT Growlers, Shirts and Membership before the Rush!


Home Brew Forums > Home Brewing Beer > Electric Brewing > Help setting up 3 phase
Reply
 
LinkBack Thread Tools
Old 04-25-2012, 12:24 PM   #1
tektonjp
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: ohmihachiman, Japan
Posts: 695
Liked 64 Times on 44 Posts
Likes Given: 56

Default Help setting up 3 phase

I'd like to start brewing down at my shop. The main reason is I have a cinder block shed attached which would make a nice compact brew room away from all the sawdust. This room is also hosts all the electricity coming into my shop. So I would like to go electric. I understand the basics, but I sure am looking for some advice. Please keeping mind this is in JAPAN. Voltage is 100 and 200.

I have two feeds coming into my room. I have a 50 amp single phase. Most of this goes to the 40 amp sub-panel in my workshop (seems small, doesn't it?). And I also have a 3 phase feed which has a 30 amp main breaker on it. This one only is used (for now) to power an old A/C unit on occasion in the summer. My question: how can I use this 3 phase for brewing? What are my options? I know there are ways to split the legs, but how does that work? What size of element(s) can I use with this?

I normally brew 5 gallon/ 20 liter batches. I'd like to probably set up a 3 vessel system, perhaps using an old 5 gallon round igloo for HLT. Single pump and a CFC is also on hand.

__________________

"Beer, well respected and rightly consumed, can be a gift of God. It is one of his mysteries, which it was his delight to conceal and the glory of kings to search out."

The Search for God and Guinness by Stephen Mansfield


Reason: correction
tektonjp is offline
 
Reply With Quote Quick reply to this message
Old 04-25-2012, 06:28 PM   #2
Henrythe9th
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2010
Location: Redmond OR, Oregon
Posts: 327
Liked 5 Times on 5 Posts
Likes Given: 12

Default

you can use any 2 out of the 3ph for single phase so you could size your elements at max for 200volt 25amps, I dont have any way of finding your voltage elements over here
good luck

__________________
Henrythe9th is offline
 
Reply With Quote Quick reply to this message
Old 04-25-2012, 08:37 PM   #3
kenmunkholm
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2012
Location: Kelowna, BC
Posts: 6
Likes Given: 2

Default

Unsure of the codes in Japan...

In Canada, loading is 80%. 80% of 30 is 24A.

You could probably get away with 5kW elements. (200V * 25A = 5000W)
A regular 5kW element rated at 208/240VAC would work, but as you would be operating at a lesser voltage, it will under perform a bit, but that should make you safe.

#10 wire here, 5.5mm over there.

EDIT:
And to really answer your question, yes, phase to phase should get you what you need. Just treat it as a 240V circuit over here.

... I always seem to be hung up on codes, but if you follow the code you have a lot of empirical evidence behind you.

__________________
kenmunkholm is offline
 
Reply With Quote Quick reply to this message
Old 04-25-2012, 11:45 PM   #4
BeerguyNC61
Senior Member
HBT_SUPPORTER.png
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2012
Location: Annapolis, MD
Posts: 541
Liked 65 Times on 49 Posts
Likes Given: 10

Default

Another issue with power in Japan is it runs on 50 hz not 60 hz. So if you get anything that has a electric timer it will run 10 minutes slow every hour. It was a pain at first when I was stationed there living off base and having to figure out the auto brew on the coffee pot.......

__________________
BeerguyNC61 is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 12:31 AM   #5
tektonjp
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: ohmihachiman, Japan
Posts: 695
Liked 64 Times on 44 Posts
Likes Given: 56

Default

Quote:
Originally Posted by BeerguyNC61 View Post
Another issue with power in Japan is it runs on 50 hz not 60 hz. So if you get anything that has a electric timer it will run 10 minutes slow every hour. It was a pain at first when I was stationed there living off base and having to figure out the auto brew on the coffee pot.......
Must be why I feel years behind!
__________________

"Beer, well respected and rightly consumed, can be a gift of God. It is one of his mysteries, which it was his delight to conceal and the glory of kings to search out."

The Search for God and Guinness by Stephen Mansfield

tektonjp is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 12:53 AM   #6
BeerguyNC61
Senior Member
HBT_SUPPORTER.png
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2012
Location: Annapolis, MD
Posts: 541
Liked 65 Times on 49 Posts
Likes Given: 10

Default

Lol

__________________
BeerguyNC61 is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 01:01 AM   #7
P-J
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2010
Location: Charlotte, NC
Posts: 3,284
Liked 260 Times on 207 Posts
Likes Given: 459

Default

Quote:
Originally Posted by BeerguyNC61 View Post
Another issue with power in Japan is it runs on 50 hz not 60 hz. So if you get anything that has a electric timer it will run 10 minutes slow every hour. It was a pain at first when I was stationed there living off base and having to figure out the auto brew on the coffee pot.......
Wait..
The Auber Instruments PID SYL-2352 has a powe input of:
"Power supply voltage rating 85~264VAC/50~60Hz"
__________________
P-J is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 03:41 AM   #8
mux
Feedback Score: 3 reviews
Recipes 
 
Join Date: Sep 2011
Location: Chicago, IL - Illinois
Posts: 1,878
Liked 67 Times on 55 Posts
Likes Given: 23

Default

Send P-J gifts! He has lent out his brain to lots of brewers building electric home breweries.

__________________
mux is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 04:21 AM   #9
tektonjp
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: ohmihachiman, Japan
Posts: 695
Liked 64 Times on 44 Posts
Likes Given: 56

Default

Quote:
Originally Posted by BeerguyNC61
Another issue with power in Japan is it runs on 50 hz not 60 hz. So if you get anything that has a electric timer it will run 10 minutes slow every hour. It was a pain at first when I was stationed there living off base and having to figure out the auto brew on the coffee pot.......
Actually, Japan had two different grids. Tokyo and Eastern Japan runs at 50 hz, and Western Japan runs at 60 hz. Most modern appliances are dual. Often though, motors will be wound for a specific frequency. I don't think an element would be affected by one or the other, although the stated wattage will be less because of the voltage, right?
__________________

"Beer, well respected and rightly consumed, can be a gift of God. It is one of his mysteries, which it was his delight to conceal and the glory of kings to search out."

The Search for God and Guinness by Stephen Mansfield

tektonjp is offline
 
Reply With Quote Quick reply to this message
Old 04-26-2012, 04:23 AM   #10
tektonjp
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: ohmihachiman, Japan
Posts: 695
Liked 64 Times on 44 Posts
Likes Given: 56

Default

So if I have a 4500 watt element in the both the HLT and the BK, I could theoretically have both on at the same time (if I were brewing back to back)?

__________________

"Beer, well respected and rightly consumed, can be a gift of God. It is one of his mysteries, which it was his delight to conceal and the glory of kings to search out."

The Search for God and Guinness by Stephen Mansfield

tektonjp is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
Question about setting up an EHERMS. sethhobrin Electric Brewing 9 07-26-2013 09:24 PM
Safely setting up 120v. Old Apartment. Vendrixfly Electric Brewing 7 03-07-2012 10:03 PM
Auber COOL setting help Twang Electric Brewing 5 05-13-2011 12:43 AM
Reality is setting in ... I need some advice GRHunter Electric Brewing 14 04-10-2011 02:43 PM
Anyone ever hear of a 3-heat (2 phase) element? mattd2 Electric Brewing 4 01-07-2011 03:59 AM



Newest Threads