New Giveaway - Wort Monster Conical Fermeneter!

Home Brew Forums > Home Brewing Beer > Electric Brewing > Dual AMP/ Volt meter wiring help




Reply
 
LinkBack Thread Tools Display Modes
Old 11-13-2013, 01:52 AM   #1
everty2007
Feedback Score: 0 reviews
 
everty2007's Avatar
Recipes 
 
Join Date: Jan 2012
Location: Sheboygan, WI
Posts: 77
Liked 6 Times on 6 Posts
Likes Given: 1

Default Dual AMP/ Volt meter wiring help

Hey Guys,

I found a dual amp/ volt meter on ebay that went with the colors of my PIDs.

After receiving this meter I'm not sure what I need to do to wire this up without bowing it up lol. So once again I thought that I would see what the ever so helpful minds of HBT thought.

So part of the reason I bought it was that I thought the transformer was built in, but it came with a small circular transformer pictured in wiring diagram with two wires coming from it.

So not being an electrician, I was wondering if anyone had any thoughts based on these diagrams, I have built a Kal inspired set up but did not install the meter originally because I have a smaller enclosure and did not have room for both meters, but would like to add this dual one. Any advice would be appreciated and thanks for taking the time to read my post.

Cheers!







__________________
everty2007 is online now
phlipot89 Likes This 
Reply With Quote Quick reply to this message
Old 11-13-2013, 02:32 AM   #2
atoughram
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2013
Location: Puyallup, Washington
Posts: 644
Liked 71 Times on 66 Posts
Likes Given: 105

Default

Are you using 220Vac or 110Vac?

If you want to measure incoming voltage and current, run jumper wires from the black and white wires coming from the plug/breaker to the "Input Voltage" connection and put the current transformer (The little doughnut thingy) around the incoming black wire. Connect the current transformer to the "Input Current" terminals.

Without seeing the system that's my best guess.



__________________
Clover Creek Brewery, Puyallup WA
Planning - Ichter Hill IPA
Fermenters - Mulholland Apple Cider, Lunch Swamp Saison OG 1.057
On tap
Ichter Hill IPA OG 1.068, Carbon River Hefeweizen OG 1.042, End of Year MMaSH Porter OG 1.061
atoughram is offline
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 02:41 AM   #3
everty2007
Feedback Score: 0 reviews
 
everty2007's Avatar
Recipes 
 
Join Date: Jan 2012
Location: Sheboygan, WI
Posts: 77
Liked 6 Times on 6 Posts
Likes Given: 1

Default

Sorry I forgot I'm running 240

Ok so I do run the wires through the doughnut thingy lol.

Sounds like a start. I'll take some pics of the setup tomorrow when I give it a try. Thanks

__________________
everty2007 is online now
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 05:30 AM   #4
The10mmKid
Feedback Score: 0 reviews
 
The10mmKid's Avatar
Recipes 
 
Join Date: Jul 2013
Location: Home of the Wright Brothers
Posts: 353
Liked 23 Times on 23 Posts
Likes Given: 105

Default

Your two voltage wires can be hooked across the two hot at the most convenient location. Length of wire, not an issue.

What are you wanting to read the amperage on?
Entire system?

Just the heating element?

Load on a circulation pump?

Basically there will be one wire passing through the current transformer.
If it's the element, pass one and only one of the hot wires through the loop. Try to keep the coil away from any other wires, especially high current ones. A few inches is best.

This too can be in a remote location with extensions on the loop OK.

'da Kid

__________________
The10mmKid is offline
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 03:08 PM   #5
processhead
Feedback Score: 0 reviews
 
processhead's Avatar
Recipes 
 
Join Date: Oct 2007
Location: Nebraska
Posts: 576
Liked 75 Times on 63 Posts
Likes Given: 3

Default

Just out of curiosity, how will you use this information while brewing? Will it make your brewing easier, or your beer better?

__________________

How hard can it be?

processhead is offline
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 06:55 PM   #6
everty2007
Feedback Score: 0 reviews
 
everty2007's Avatar
Recipes 
 
Join Date: Jan 2012
Location: Sheboygan, WI
Posts: 77
Liked 6 Times on 6 Posts
Likes Given: 1

Default

Quote:
Originally Posted by processhead
Just out of curiosity, how will you use this information while brewing? Will it make your brewing easier, or your beer better?
This will contribute absolutely nothing to my brewing process. It's more cosmetic and for monitoring the system and nothing to do with my beer.

When I built the system I didn't install one and found the meter I liked and decided to give it a try.

Thanks good question.
__________________
everty2007 is online now
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 07:22 PM   #7
BigFloppy
Feedback Score: 8 reviews
Recipes 
 
Join Date: Aug 2013
Location: Marietta, GA
Posts: 327
Liked 21 Times on 15 Posts
Likes Given: 4

Default

Quote:
Originally Posted by processhead View Post
Just out of curiosity, how will you use this information while brewing? Will it make your brewing easier, or your beer better?
As a tech support engineer, I feel obligated to answer this question.

If there's numbers showing on the Volts/Amps panel, he is brewing. Everyone who knows him recognizes this as the sign for impromptu free beer cause it's brewing day

If there's no numbers showing on the panel he's either thinking about brewing or has just finished
__________________
BigFloppy is offline
wuttheheeck Likes This 
Reply With Quote Quick reply to this message
Old 11-13-2013, 07:37 PM   #8
dyqik
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jun 2013
Location: Arlington, MA, Massachusetts
Posts: 396
Liked 46 Times on 43 Posts
Likes Given: 1

Default

The current numbers will tell him if he's accidentally left an element on or off. The voltage numbers will tell him if his rig is making the neighbor's lights dim.

__________________
dyqik is offline
tator2k Likes This 
Reply With Quote Quick reply to this message
Old 11-13-2013, 08:22 PM   #9
processhead
Feedback Score: 0 reviews
 
processhead's Avatar
Recipes 
 
Join Date: Oct 2007
Location: Nebraska
Posts: 576
Liked 75 Times on 63 Posts
Likes Given: 3

Default

Quote:
Originally Posted by BigFloppy View Post
As a tech support engineer, I feel obligated to answer this question.

If there's numbers showing on the Volts/Amps panel, he is brewing. Everyone who knows him recognizes this as the sign for impromptu free beer cause it's brewing day

If there's no numbers showing on the panel he's either thinking about brewing or has just finished
Agreed.
But for the betterment of the entire brewing/drinking community, this data will need to be streamed in real-time to HBT's website.
__________________

How hard can it be?

processhead is offline
 
Reply With Quote Quick reply to this message
Old 11-13-2013, 08:51 PM   #10
The10mmKid
Feedback Score: 0 reviews
 
The10mmKid's Avatar
Recipes 
 
Join Date: Jul 2013
Location: Home of the Wright Brothers
Posts: 353
Liked 23 Times on 23 Posts
Likes Given: 105

Default

Quote:
Originally Posted by processhead View Post
Just out of curiosity, how will you use this information while brewing? Will it make your brewing easier, or your beer better?
Assuming Everty is monitoring the element . . . . .
1) Verify the element is good. You can have a Zillion volts, but no current flow means no heating
2) While in operation, he can perform some math and tell us exactly what wattage those manufacturers are selling us.
3) The BLING factor is priceless.

'da Kid


__________________
The10mmKid is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools
Display Modes


Similar Threads
Thread Thread Starter Forum Replies Last Post
Wiring Help - Digitial Volt Meter / Ammeter Jps101 Electric Brewing 6 05-29-2013 04:48 AM
volt & amp meter placement on the control box rustybeer Electric Brewing 4 03-16-2013 03:47 PM
Problems with my Volt Meter acefaser Electric Brewing 13 01-03-2012 03:01 PM
AMP & Volt Meter questions / problems. rvklein Electric Brewing 5 02-09-2011 12:44 PM