Default contactor recommendation

so i go to test my control panel for the first time plug it it turn the switch and nothing... better than smoke but as it turns out i mistakenly got the wrong contactor. i had them wired as being 24v coils instead they are 220v. 120v will move the coil but it bounces like crazy and makes an awful racket.

So what I have is a 50amp service coming to the box and each leg going through a contactor. What is a good single contactor that can handle 50 amps and is quiet that runs on 120v. One of the benefits of moving to electric was being quiet.

Would this be the way to go?
http://www.automationdirect.com/adc/.../SC-E2S-110VAC


Any advice would be greatly appreciated.

__________________

Reason: added link
jcalisi is offline
 
Reply With Quote Quick reply to this message
Old 06-05-2011, 04:34 AM   #2
HHP
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: Harker Heights, Texas
Posts: 374
Liked 6 Times on 5 Posts
Likes Given: 2

Default

This one should do it for you:

http://www.hottubworks.com/cgi-bin/c...-CON-50ADP120C

Not a terrible price either...

__________________
HHP is offline
 
Reply With Quote Quick reply to this message
Old 06-05-2011, 12:07 PM   #3
jcalisi
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2009
Location: Mount Juliet, TN
Posts: 169
Liked 2 Times on 2 Posts

Default

Thanks HHP. The price is right... How much noise should I expect from something like this.

__________________
jcalisi is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 09:27 AM   #4
HHP
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2010
Location: Harker Heights, Texas
Posts: 374
Liked 6 Times on 5 Posts
Likes Given: 2

Default

No idea, I just google product searched and found it

I have two 30A contactors sitting at home, but I wont be back until august, so I guess I could answer then...

__________________
HHP is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 05:53 PM   #5
Walker
I use secondaries. :p
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Walker's Avatar
Recipes 
 
Join Date: Sep 2005
Location: Cary, NC
Posts: 11,236
Liked 86 Times on 77 Posts
Likes Given: 11

Default

ebay. $20:

http://cgi.ebay.com/NEW-AC-HEATING-CONTACTOR-CN-PBC402-120V-40-50a-2p-/390172629860?pt=LH_DefaultDomain_0&hash=item5ad819 db64

edit: regarding noise: you shouldn't really be getting any noise. When you turn them on they will make that one-time "CLACK", but they they just stay on. Maybe a very slight (meaning, you will have to TRY to hear it) "hum".

__________________
Ground Fault Brewing Co.
Walker is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 06:00 PM   #6
jcalisi
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2009
Location: Mount Juliet, TN
Posts: 169
Liked 2 Times on 2 Posts

Default

Thanks Walker. I just bought the 4 pole from the same guy. I hope this thing isn't too noisy... I wanted a i AB iec contactor but way more than I can spend right now.

__________________
jcalisi is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 06:03 PM   #7
Walker
I use secondaries. :p
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Walker's Avatar
Recipes 
 
Join Date: Sep 2005
Location: Cary, NC
Posts: 11,236
Liked 86 Times on 77 Posts
Likes Given: 11

Default

Quote:
Originally Posted by jcalisi View Post
Thanks Walker. I just bought the 4 pole from the same guy. I hope this thing isn't too noisy... I wanted a i AB iec contactor but way more than I can spend right now.
Interesting. Why 4-pole?
__________________
Ground Fault Brewing Co.
Walker is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 06:05 PM   #8
Walker
I use secondaries. :p
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Walker's Avatar
Recipes 
 
Join Date: Sep 2005
Location: Cary, NC
Posts: 11,236
Liked 86 Times on 77 Posts
Likes Given: 11

Default

I see a 4-pole with a 240V coil, but I don't even see a 4-pole that operates on 120V from that seller.

__________________
Ground Fault Brewing Co.
Walker is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 08:17 PM   #9
jcalisi
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2009
Location: Mount Juliet, TN
Posts: 169
Liked 2 Times on 2 Posts

Default

I have my power coming into a small distribution box and then it will feed the contactor. I will wire the contactor as if its two and load balance my components across it. Not to mention it was the same price as the 3p... I'll shoot some pictures once I have it installed. I'm so ready to have this thing running.

__________________
jcalisi is offline
 
Reply With Quote Quick reply to this message
Old 06-06-2011, 10:42 PM   #10
bthorn9435
Feedback Score: 0 reviews
Recipes 
 
Join Date: Oct 2010
Location: NC
Posts: 74
Default

Wouldn't a Definite Purpose Contactor work for this application. I work in the electrical
industry and I know SQD has a good assortment of these.

__________________
bthorn9435 is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
SSR, Contactor? both? help me K.I.S.S mavrick1903 Electric Brewing 19 02-13-2013 05:57 AM
Looking for a 2 pole Contactor, 30A, 120V Coil that is Din rail mountable Windsors Electric Brewing 21 01-02-2012 05:39 AM
Contactor question GRHunter Electric Brewing 3 05-25-2011 11:32 AM
Contactor load HHP Electric Brewing 3 05-03-2011 01:13 AM
Mercury contactor vs. SSR burglar Electric Brewing 8 01-26-2011 01:48 AM