Default 50 amp vs 30 amp

I am trying to decide if I really need 50a service from my breaker box. I have a new house with plenty of room in the box so that is not a problem. The cost is significantly greater though and I am slowly getting SWMBO's approval but keeping the price down makes it easier to convince her. I am trying to figure out what the advantage is to having 50 amps is. I only plan on 5 to 10 gal batches and batch sparging in a cooler mash tun. It would be 2 tier with one pump maybe upgraded to single tier HERMS with 2 pumps later on. I would like to use 2 5500w elements but could use 4500w if that would be too much for 30 amp. From what I have read it seems that I just wouldn't be able to run the BK and HLT at the same time.

__________________
BWN is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 01:42 PM   #2
Rbeckett
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
Rbeckett's Avatar
Recipes 
 
Join Date: Dec 2011
Location: Bronson, Fl
Posts: 987
Liked 66 Times on 47 Posts
Likes Given: 29

Default

Where in your home do you plan to use this power outlet? If in the garage or "outside" then 50 amps or more is a good idea. Y ou never know when you might decide to weld, or upgrade to a big water heater and several heating elements on your tower. If you can afford it go with the 50amps just to insure you have what you need now and well into the future. SWMBO will never go for an expensive "upgrade" later on since you spent money the first time. Just my .02, but it is easier to ask for forgiveness than to get more money later.
Have fun, just don't piss her off....
Bob

__________________

What do you mean "no Kidneys"???, WTF now I gotta drink less beer...
Join the Automation sub forum in Electric brewing for a discussion of components and control systems. I did!!!!


Reason: spelling
Rbeckett is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 01:49 PM   #3
WAORGANY
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
WAORGANY's Avatar
Recipes 
 
Join Date: Apr 2010
Location: Northern NY, NY
Posts: 470
Liked 14 Times on 12 Posts
Likes Given: 34

Default

Quote:
Originally Posted by BWN View Post
I am trying to decide if I really need 50a service from my breaker box. I have a new house with plenty of room in the box so that is not a problem. The cost is significantly greater though and I am slowly getting SWMBO's approval but keeping the price down makes it easier to convince her. I am trying to figure out what the advantage is to having 50 amps is. I only plan on 5 to 10 gal batches and batch sparging in a cooler mash tun. It would be 2 tier with one pump maybe upgraded to single tier HERMS with 2 pumps later on. I would like to use 2 5500w elements but could use 4500w if that would be too much for 30 amp. From what I have read it seems that I just wouldn't be able to run the BK and HLT at the same time.
Brian,

I think I am just going with 30 AMP...can always upgrade later if needed. I cut my kegs this morning, cutting the old one was a pain but got it ok, and the other one was pretty easy...going to start working on the electrical control box now....
__________________

RLTW!

WAORGANY is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 01:50 PM   #4
mabrungard
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2011
Location: Carmel, IN
Posts: 2,768
Liked 192 Times on 165 Posts
Likes Given: 24

Default

Two 5500w elements firing at the same time for a long duration is way too much for a 30a circuit and may be still too much for a 50a circuit. A 4500w and 5500w element firing together should be OK for long term use on a 50a circuit.

If the plan is to run a 5500w element in the various brewery components at separate times, then the 30a will be fine. I know that in my case, I will be wanting to heat my sparge water while I'm still running my RIMS. That means that I would have been toying with the potential of tripping a 30a circuit under that condition. I opted for 50a and run my RIMS with 4500w and the HLT with 5500w. Its good.

__________________

Martin B
Carmel, IN
BJCP National
Foam Blowers of Indiana (FBI)

Brewing Water Information at:
https://sites.google.com/site/brunwater/

Like Bru'n Water on Facebook for occasional discussions on brewing water and Bru'n Water

mabrungard is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 02:31 PM   #5
CourtHouseBrewing
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2012
Location: Orlando, Fl
Posts: 128
Liked 2 Times on 2 Posts
Likes Given: 4

Default

I would have gone with a dedicated 60 amp service to your brew area if it were me. If you are talking about a HERMS system you will probably not stop there. It might be more money up front but less than up grading later. You don’t want to have a power failure in the middle of your brew day. The other option is to supplement with propane unless this is all inside brewing, then I would put a hood over the kettle. My next house will have a custom brew room. I’m not Obsessed, no I’m addicted to brewing!

__________________
CourtHouseBrewing is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 02:32 PM   #6
BWN
Feedback Score: 0 reviews
Recipes 
 
Join Date: Dec 2010
Location: Dexter, NY
Posts: 701
Liked 20 Times on 19 Posts
Likes Given: 3

Default

Quote:
Originally Posted by Rbeckett View Post
Where in your home do you plan to use this power outlet? If in the garage or "outside" then 50 amps or more is a good idea. Y ou never know when you might decide to weld, or upgrade to a big water heater and several heating elements on your tower. If you can afford it go with the 50amps just to insure you have what you need now and well into the future. SWMBO will never go for an expensive "upgrade" later on since you spent money the first time. Just my .02, but it is easier to ask for forgiveness than to get more money later.
Have fun, just don't piss her off....
Bob
The power outlet will be in the basement about 50 feet from my breaker box. I have a gas powered hot water heater and have access to welders where I work so I can't really see a need for the outlet other than brewing.

Thanks for the replies it eases my mind that it is possible to accomplish what I need for little less $
__________________
BWN is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 02:57 PM   #7
Bernie Brewer
Grouchy Old Fart
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Bernie Brewer's Avatar
Recipes 
 
Join Date: Feb 2006
Location: Eldorado, WI
Posts: 7,539
Liked 116 Times on 52 Posts
Likes Given: 2

Default

5500w/240v=23 amps. That by itself is pushing it for a 30 amp circuit, much less two of them. If you are going to run 2 elements at once I would at the very least go with a 50A circuit and use a 4500w and 5500w. If only using one at a time, then go ahead with the 5500w but I would bump the circuit size to 40A.

__________________
I like to squeeze the nickle until the buffalo craps-mt rob

"Why don't we get drunk and screw?" Jimmy Buffett
Bernie Brewer is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 03:49 PM   #8
BWN
Feedback Score: 0 reviews
Recipes 
 
Join Date: Dec 2010
Location: Dexter, NY
Posts: 701
Liked 20 Times on 19 Posts
Likes Given: 3

Default

Quote:
Originally Posted by Bernie Brewer View Post
5500w/240v=23 amps. That by itself is pushing it for a 30 amp circuit, much less two of them. If you are going to run 2 elements at once I would at the very least go with a 50A circuit and use a 4500w and 5500w. If only using one at a time, then go ahead with the 5500w but I would bump the circuit size to 40A.
I can get away with running just one at a time.
__________________
BWN is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 04:24 PM   #9
zeus53219
HBT_SUPPORTER.png
Feedback Score: 2 reviews
 
zeus53219's Avatar
Recipes 
 
Join Date: Oct 2010
Location: Milwaukee
Posts: 294
Liked 7 Times on 6 Posts

Default

I'm using a 30A circuit running 2 5500w elements(one at a time) with 2 pumps running consistently, and I have no problems. Ive taken several amp draws and the max reading was 26.3A.

__________________
zeus53219 is offline
 
Reply With Quote Quick reply to this message
Old 02-12-2012, 05:04 PM   #10
WAORGANY
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
WAORGANY's Avatar
Recipes 
 
Join Date: Apr 2010