Electric Brewing Supply 30A BCS Giveaway - Last Chance to Enter!


Home Brew Forums > Home Brewing Beer > Electric Brewing > 110v Recirculating eBIAB 2.5 gallon batches
Reply
 
LinkBack Thread Tools
Old 07-07-2013, 04:43 AM   #361
Cregar
Feedback Score: 0 reviews
 
Cregar's Avatar
Recipes 
 
Join Date: May 2006
Location: Phoenix, AZ
Posts: 702
Liked 4 Times on 4 Posts
Likes Given: 4

Default

Bump

__________________
Cregar is offline
 
Reply With Quote Quick reply to this message
Old 07-07-2013, 07:44 AM   #362
Carlscan26
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
Carlscan26's Avatar
Recipes 
 
Join Date: Jun 2012
Location: San Diego, CA
Posts: 588
Liked 41 Times on 37 Posts
Likes Given: 27

Default

Quote:
Originally Posted by Cregar
Bump
I don't think so - the stc can't react fast enough to make the temp adjustments needed.
__________________
Carlscan26 is offline
 
Reply With Quote Quick reply to this message
Old 07-10-2013, 03:23 AM   #363
Salpino
HBT_SUPPORTER.png
Feedback Score: 1 reviews
 
Salpino's Avatar
Recipes 
 
Join Date: Jun 2011
Posts: 99
Liked 26 Times on 10 Posts
Likes Given: 13

Default

I see machine screws used to mount the contactor and bus bar to the Auber box. Any issue with using JB Weld to mount them to the inside of a structural foam water resistant tool box?

__________________
Salpino is offline
 
Reply With Quote Quick reply to this message
Old 07-10-2013, 01:31 PM   #364
jeffmeh
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
jeffmeh's Avatar
Recipes 
 
Join Date: Feb 2009
Posts: 1,854
Liked 140 Times on 121 Posts
Likes Given: 18

Default

Quote:
Originally Posted by Salpino View Post
I see machine screws used to mount the contactor and bus bar to the Auber box. Any issue with using JB Weld to mount them to the inside of a structural foam water resistant tool box?
It would be a pain in the neck if you ever had to replace a component, or move one temporariliy to get into a tight space. Why not use a sheet of plastic or metal as a backplate for mounting the componenets?
__________________
jeffmeh is offline
P-J Likes This 
Reply With Quote Quick reply to this message
Old 07-13-2013, 05:37 PM   #365
Cregar
Feedback Score: 0 reviews
 
Cregar's Avatar
Recipes 
 
Join Date: May 2006
Location: Phoenix, AZ
Posts: 702
Liked 4 Times on 4 Posts
Likes Given: 4

Default

Quote:
Originally Posted by Carlscan26 View Post
I don't think so - the stc can't react fast enough to make the temp adjustments needed.
thanks... appreciate the reply
__________________
Cregar is offline
 
Reply With Quote Quick reply to this message
Old 07-13-2013, 06:49 PM   #366
Salpino
HBT_SUPPORTER.png
Feedback Score: 1 reviews
 
Salpino's Avatar
Recipes 
 
Join Date: Jun 2011
Posts: 99
Liked 26 Times on 10 Posts
Likes Given: 13

Default

Quote:
Originally Posted by jeffmeh

It would be a pain in the neck if you ever had to replace a component, or move one temporariliy to get into a tight space. Why not use a sheet of plastic or metal as a backplate for mounting the componenets?
Good call--didn't think about replacing a part. Also, I need to figure a way to mount the heat sink metal to metal.
__________________
Salpino is offline
 
Reply With Quote Quick reply to this message
Old 07-18-2013, 07:54 PM   #367
Salpino
HBT_SUPPORTER.png
Feedback Score: 1 reviews
 
Salpino's Avatar
Recipes 
 
Join Date: Jun 2011
Posts: 99
Liked 26 Times on 10 Posts
Likes Given: 13

Default

Many thanks to P-J for the many diagrams he's made for all of the brewers looking to go electric.

My question, as this is my first foray with contactors: is this wired correctly per the original 120v diagram P-J posted (picture #2)?

Hot on the bottom goes to the element. Hot on the top goes to the SSR. I have not wired the hot to the switch yet.

Thanks for the help.

image-4268760354.jpg   image-1211084557.jpg  
__________________
Salpino is offline
 
Reply With Quote Quick reply to this message
Old 07-28-2013, 02:53 AM   #368
OneImpBrewery
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
OneImpBrewery's Avatar
Recipes 
 
Join Date: Jan 2013
Posts: 108
Liked 7 Times on 7 Posts
Likes Given: 6

Default Same question as above

Rigging up the coil and i keep blowing a fuse. I hooked up mine differently than the pictures but I cant quite tell how different. I have one side with the 8 plugs on it that does not have any on it. Still a little confused. Anyone have a link or a suggestion as to how I can get it correct? I thought I was doing this right from the schematic but I guess not, As i keep tripping the breaker.

Thanks for any help.

The Imp

__________________
OneImpBrewery is offline
 
Reply With Quote Quick reply to this message
Old 07-28-2013, 07:40 PM   #369
OneImpBrewery
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
OneImpBrewery's Avatar
Recipes 
 
Join Date: Jan 2013
Posts: 108
Liked 7 Times on 7 Posts
Likes Given: 6

Default Doh

Figured It out... Just like the picture above just need the hot on the left side to go to the switch. Working great. Thanks for all the hard work that everyone has put into this thread to make it possible for all of us.

Cheers

The Imp

__________________
OneImpBrewery is offline
 
Reply With Quote Quick reply to this message
Old 07-29-2013, 05:41 PM   #370
byfbo2000
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2013
Location: Hemlock, NY
Posts: 10
Liked 4 Times on 3 Posts
Likes Given: 1

Default

Very inspirational! Lot's of good information in this thread! Sure has me crunching some numbers and saving some pennies!

__________________
www.theprickers.com
www.smidgensinc.com
byfbo2000 is offline
 
Reply With Quote Quick reply to this message
Reply



Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
How to build a 5 gal, 110v eBIAB kettle Disintegr8or Electric Brewing 96 02-19-2014 08:09 PM
110v Hlt kickrjason Electric Brewing 24 07-08-2012 04:05 AM
110v to 3v??? BigPatBrewer Electric Brewing 18 05-07-2012 06:04 PM
Anybody brew 10g batches with a 2250w 110v ? joeybeer Electric Brewing 3 01-24-2012 11:40 PM