10-21-2012, 08:43 PM
|
#1
|
|
Feedback Score: 0 reviews
Join Date: Oct 2011
Location: Asheville, NC
Posts: 13
Liked 3 Times on 3 Posts
|
Stuck Fermentation - 2 Batches - 2 Yeasts. Help!
|
|
Ok, so I went to bottle my porter this afternoon and found that it was stuck at 1.030 after 40+ days. What a disappointment. Never having this problem, I already had it in the bottling bucket ready to go and had to transfer it back into the fermenter to see if I can get anything to happen again! This beer started at 1.064 (9/16/12) and was pitched with WLP002 straight from the vile (never had a problem doing this before).
Thought I had better check on the 10 gallons of WIT I brewed after the Porter and found that it too is stuck! WTF. The WIT Started @ 1.050 (9/30/12) with WLP410 and is now stuck at 1.018 (10/21/12). It was pitched directly onto the cake of my previous batch and experienced EXPLOSIVE fermentation within a day.
We have had a couple of cold snaps around here, but my basement usually stays between 65-72 year round. Also, did the same techniques as my previous (many) batches on both.
I am completely at a loss here... Anyone have any suggestions?
Would pitching more yeast help? How about a different strain to finish it up? Ive got some WLP001 at my disposal immediately... Seriously considering it, but was wondering if anyone else has some ideas.
|
|
|
10-21-2012, 08:46 PM
|
#2
|
|
Frau Administrator
Feedback Score: 0 reviews
Join Date: Jun 2006
Location: Upper Michigan
Posts: 51,735
Liked 1971 Times on 1513 Posts Likes Given: 89
|
Did you check your hydrometer to make sure it's at 1.000? You're not using a refractometer, right?
__________________
Broken Leg Brewery
Giving beer a leg to stand on since 2006
|
|
|
10-21-2012, 09:01 PM
|
#3
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2008
Location: Colora, Maryland
Posts: 4,857
Liked 215 Times on 177 Posts Likes Given: 183
|
We talking extract or AG? If your AG, you may be mashing way too high due to a faulty thermometer.
|
|
|
10-21-2012, 09:07 PM
|
#4
|
|
Feedback Score: 0 reviews
Join Date: Oct 2011
Location: Asheville, NC
Posts: 13
Liked 3 Times on 3 Posts
|
Quote:
Originally Posted by Yooper
Did you check your hydrometer to make sure it's at 1.000? You're not using a refractometer, right?
|
Yes, put it in some water for a 1.000 right away.
|
|
|
10-21-2012, 09:11 PM
|
#5
|
|
Feedback Score: 0 reviews
Join Date: Oct 2011
Location: Asheville, NC
Posts: 13
Liked 3 Times on 3 Posts
|
Quote:
Originally Posted by Hammy71
We talking extract or AG? If your AG, you may be mashing way too high due to a faulty thermometer.
|
I always use multiple thermometers: One on my brew kettle for heating mash water, a digital food thermometer, and a candy/deep fry old school thermo. They all match on another within about 3-4 degrees consistently.
These are definitely not through, tasting them leaves little to no trace of alcohol and obvious sweetness still in the wort.
|
|
|
10-22-2012, 12:50 AM
|
#6
|
|
Frau Administrator
Feedback Score: 0 reviews
Join Date: Jun 2006
Location: Upper Michigan
Posts: 51,735
Liked 1971 Times on 1513 Posts Likes Given: 89
|
Quote:
Originally Posted by clblittle
I always use multiple thermometers: One on my brew kettle for heating mash water, a digital food thermometer, and a candy/deep fry old school thermo. They all match on another within about 3-4 degrees consistently.
These are definitely not through, tasting them leaves little to no trace of alcohol and obvious sweetness still in the wort.
|
But a 4 degree difference is HUGE! If you think you're mashing at 156, and are actually at 160, the beer will be a totally different beer and finish sweet with a high FG.
If your mash temp varies by that much, that could be the cause of the problem.
__________________
Broken Leg Brewery
Giving beer a leg to stand on since 2006
|
|
|
10-22-2012, 01:02 AM
|
#7
|
|
Feedback Score: 0 reviews
Join Date: Aug 2012
Location: Rochester, MN
Posts: 24
Liked 2 Times on 2 Posts Likes Given: 1
|
The variability between thermometers, even among the same model, is surprisingly bad. Unless you fork out big bucks for a lab grade meter, there can be as much as 3-4 degrees variance. Try to use one that at least can be calibrated at 32F in ice water.and check the spec for accuracy.
__________________
Sláinte mhaith !
SaazAll
|
|
|
10-22-2012, 02:18 AM
|
#8
|
|
Feedback Score: 0 reviews
Join Date: Oct 2008
Location: Americas Hinterland, Wisconsin
Posts: 1,574
Liked 20 Times on 19 Posts Likes Given: 205
|
It's my understanding that extract batches might finish a couple thousandths higher gravity. The 1.018 might be complete.
The 1.030 - a lot of people will disagree with me - a lot - do a little research and consider aerating it and pitching a little more yeast.
I wouldn't bottle it like that.
|
|
|
10-22-2012, 01:22 PM
|
#9
|
|
Feedback Score: 0 reviews
Join Date: Oct 2011
Location: Asheville, NC
Posts: 13
Liked 3 Times on 3 Posts
|
Well, I "shook" up the porter and see a little bit of activity this morning in the airlock. Ive got my fingers crossed that it is going to get going again. Seriously hoping it isnt just out-gassing the air I shook into it.
On the WIT, if it doesn't move in a week or so I am just going to live with it. It tastes good, so it might be better as a low alcohol session beer. Ill just be sure to keg it rather then bottle.
As far as thermometers, I hear you. Without the funds for a high end thermo, what are you all using? I always figured that by keeping track on multiple thermos, I had my bases covered and was probably hitting within a reasonable range. Might be wrong on that one.
I usually mash in low and raise the temp to my target. Target on each of these was 150, which I hit on both. So even if the thermo is off by 4 deg., 154 isn't a deal breaker as far as fermentable sugar is it? Just changes the beers taste, right?
I appreciate your help as always! Learning something new here almost everyday!
|
|
|
10-22-2012, 11:40 PM
|
#10
|
|
Feedback Score: 0 reviews
Join Date: Oct 2011
Location: Asheville, NC
Posts: 13
Liked 3 Times on 3 Posts
|
It official: Porter is back up.
Guess I need to get myself some aeration equipment. A problem solved and an excuse to get a new toy. 
|
|
|
| Thread Tools |
|
|
| Display Modes |
Linear Mode
|
|
|
|