So....like a lot of us I have 2 hydrometers incase one breaks...which well has happened a time or two.

Now comes my lesson, use the same hydrometer for all your readings though out the fermentation. Using the same sample the difference between the two hydrometers is .015 (give or take a little).

It only took me 2 months to figure out why my efficiency has been all over the place using the same equipment and same process. Not to mention when you are trying to get a final gravity reading.

I have marked one now to tell the difference, but one of these days I really should switch to a refractometer.

__________________
The_Mad_Scientist is offline
 
Reply With Quote Quick reply to this message
Old 08-17-2013, 04:10 AM   #2
BigFloyd
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
BigFloyd's Avatar
Recipes 
 
Join Date: Dec 2012
Location: Tyler, Texas
Posts: 4,802
Liked 626 Times on 548 Posts
Likes Given: 575

Default

I have two hydrometers. One reads .002 high, the other .002 low. I marked each one and compensate for the error.

I love my refractometer when doing AG batches. Once the batch is in the fermenter, however, I put it away in its zippered pouch and use the hydrometers. Even with the alcohol correction calculations, I'm not confident that I can get an accurate reading with the refractometer.
__________________
Good Temp Control -----> Happy Yeast ------> Tasty Brew
BigFloyd is offline
 
Reply With Quote Quick reply to this message
Old 08-17-2013, 03:14 PM   #3
GotPushrods
Bearded Lagerjack
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
GotPushrods's Avatar
Recipes 
 
Join Date: Jul 2012
Location: Phoenix, AZ
Posts: 339
Liked 56 Times on 41 Posts
Likes Given: 6

Default

Quote:
Originally Posted by The_Mad_Scientist
Using the same sample the difference between the two hydrometers is .015 (give or take a little).
Wow, never seen one off so badly. So one will read 1.050, and the other 1.065?? Is this temp corrected?

What do they read in distilled water?
__________________
GotPushrods is offline
 
Reply With Quote Quick reply to this message
Old 08-17-2013, 03:56 PM   #4
The_Mad_Scientist
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Chicago, IL
Posts: 53
Liked 4 Times on 2 Posts
Likes Given: 1

Default

Quote:
Originally Posted by GotPushrods View Post
Wow, never seen one off so badly. So one will read 1.050, and the other 1.065?? Is this temp corrected?

What do they read in distilled water?
Yep...if one will read 1.050 the other will be in the 1.064-1.066. in distilled water.. one reads .095 and the other 1.007-1.010 I have noticed that one tends to very in its readings...where the other pretty much is rock solid...a little off but solid.
__________________
The_Mad_Scientist is offline
 
Reply With Quote Quick reply to this message
Old 08-17-2013, 04:01 PM   #5
kh54s10
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2011
Location: Tiverton, Rhode Island
Posts: 6,419
Liked 554 Times on 470 Posts
Likes Given: 150

Default

If they are different by .015 I would try to find out if one is accurate and intentionally break the bad one. That is too big an error for me.

__________________
kh54s10 is offline
Hammy71 Likes This 
Reply With Quote Quick reply to this message
Old 08-17-2013, 11:31 PM   #6
overdbus
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2011
Location: LaVerne, Ca
Posts: 223
Liked 4 Times on 3 Posts

Default

I've seen the paper inside slip down , that was just wonderful trying to
figure out why everything was off...

__________________
overdbus is offline
 
Reply With Quote Quick reply to this message
Old 08-18-2013, 06:02 AM   #7
The_Mad_Scientist
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Chicago, IL
Posts: 53
Liked 4 Times on 2 Posts
Likes Given: 1

Default

I am guessing there must be some form of manufacturing error....they are relatively cheap equipment... So my bet is quality control is not as tight as commercial lab equipment.

I will end up only using the one that keeps a consistent reading and manually correct


anyone want a slightly used refractometer cheap

__________________
The_Mad_Scientist is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
New Lesson Learned... phrogpilot73 Bottling/Kegging 1 04-23-2011 02:42 PM
Lesson learned! Bigbens6 General Beer Discussion 1 12-14-2008 11:00 PM
Lesson learned..........again. Brewer3401 Equipment/Sanitation 1 08-14-2007 08:43 AM
First lesson learned distrex Beginners Beer Brewing Forum 7 02-10-2007 11:36 PM