Quote:
Originally Posted by ajdelange
How would I know they can be off by a Bx or more if I didn't have one?
|
You could have read an article, heard from a friend, seen it in a forum and so on. I was wanting to know if you owned one and used it on a regular basis and how you liked it.
Quote:
Originally Posted by ajdelange
I like the idea too. That's why I got a couple and started checking them out against hydrometer and density meter. I didn't find the agreement that good. Unfortunately I'm overseas at the moment and can't look at my notes or I'd be more specific.
|
You have a couple digital refractometers? Which models? Which one are you ok with?
Quote:
Originally Posted by ajdelange
Post fermentation it's necessary to correct for alcohol content so I assume that you are doing that as well. There are several spreadsheets about that will do this for you (e.g the one from MoreBeer which corrects for alcohol and temperature based on original refractometer reading).
|
Of course. I use a version of the More Beer sheet that I added a few features to, Attenuation, Rate, ABV, Estimated Completion and a graph. I feel the formula they use is pretty accurate although I do recall a podcast where somebody said they had a better one. Also, even if you didn’t compensate for alcohol, you could still use a refractometer to see if fermentation is occurring. Once the numbers stop dropping, break out the hydrometer.
Quote:
Originally Posted by ajdelange
Refractometers are, of course, great for monitoring progress of sparging or fermentation. Beyond that, I'm not too keen on them.
|
I use my analog refractometer for sparging, monitoring evaporation rate, OG, Fermentation and FG. For OG and FG, I always also use a hydrometer as well. Maybe I’m lucky but my numbers are always right on. (At least within the error of how accurately I can read a refractometer or hydrometer.) For example, my current batch, an APA with an SRM of ~7, had an OG of 13.1 Brix by refractometer (1.0530 calculated) and a 1.052 hydrometer value (temp corrected 1.0533). I monitored the fermentation every ~12 hours until I had it hold steady at 6.6 for a few days (1.01074). Then I pull enough sample to check with my final gravity hydrometer where I got a reading of 1.0105 (temp corrected to 1.0108). Now I battled as to whether the 1.0105 was more of a 1.010 or a 1.0105 and finally decided on the latter. Same with the 6.6 as to if it was a 6.6 or a 6.5. I’ve had the same experiences with darker beers and ones that also include sugar. I feel confident that I could use only the refractometer for everything, but since I have one and like to taste the sample I keep using it.
My question is, if I’d have the same experience with a digital refractometer. I’d like to have a value displayed and not have to second guess my squinting at the little lines. I’ve also tried to hook up a camera but it wasn’t worth the trouble.