Advertise Here
Main · BrewSpace · Recipes · Wiki · Groups · Clubs · Gallery · Reviews · Video · Blogs · Store

Used liquor barrelsStainless AccessoriesALL NEW Rebel Mill Grain Crusher now Available at Rebel Br
Go Back   Home Brew Forums > Home Brewing Beer > Equipment/Sanitation



Reply
 
LinkBack Thread Tools Display Modes
Old 01-21-2012, 04:29 PM   #1
Senior Member
 
Grizzlybrew's Avatar
Recipes 
 
Join Date: Apr 2009
Location: Douglasville, GA
Posts: 1,180
Default What Size Pump for 1/2" x 50 ft Immersion Chiller?

I am using the Morebeer WC30 1/2" x 50 ft Immersion Chiller. I want to use a recirculating pond pump and just purchased the following:

Total Pond 285-525 GPH Fountain Pump (MD11500X) from The Home Depot

The pump can accomodate a 3/8", 1/2" or 3/4" hose and has the following output:

585 gph @ 0 ft
500 gph @ 1 ft
191 gph @ 6 ft
0 gph @ 8.7 ft

There's a lot of discussion about pumps with chillers, but not much dealing with this size chiller. Is this pump sufficient to push chill water through the WC30 IC at an adeqaute cooling rate? My LHBS owner uses a 1400 gph pump! It seems you would have to put a valve on the output side to reduce flow a little, but he did not mention that.

The top of my chiller will be approximately 4' off the ground. If I had to I could place the cooler with the pump in it even with the kettle. I thought I may run a 3/4" hose to the chiller and let it neck-down naturally into the 1/2" copper.

Thanks for the help. Extra thanks if you have personal experience or are familiar with fluid dynamics/hydraulics/etc.


__________________
On Deck
perhaps a line of single hop IPA's - there's so many new hops out there!!!
Grizzlybrew is offline Reply With Quote
Old 01-21-2012, 04:36 PM   #2
Senior Member
Recipes 
 
Join Date: May 2009
Location: Los Angeles
Posts: 6,180
Default

Seems like that should work OK. I had one much lower rated, like maybe 200 GPH max, that I used in a 25' chiller that had about a 2 foot head height. That is really the key factor. What will be the height between the pump and the top of the chiller?

I assume you are using this to pump ice water?
weirdboy is offline Reply With Quote
Old 01-21-2012, 04:41 PM   #3
Senior Member
 
Grizzlybrew's Avatar
Recipes 
 
Join Date: Apr 2009
Location: Douglasville, GA
Posts: 1,180
Default

Quote:
Originally Posted by weirdboy View Post
Seems like that should work OK. I had one much lower rated, like maybe 200 GPH max, that I used in a 25' chiller that had about a 2 foot head height. That is really the key factor. What will be the height between the pump and the top of the chiller?

I assume you are using this to pump ice water?
Yes, it's pumping recirculating ice water from/to a cooler. As in the OP, the height could be anywhere from 4' to 0'. I prefer the 4' height but could arrange either setup.
__________________
On Deck
perhaps a line of single hop IPA's - there's so many new hops out there!!!
Grizzlybrew is offline Reply With Quote
Old 01-22-2012, 12:38 PM   #4
Senior Member
 
Grizzlybrew's Avatar
Recipes 
 
Join Date: Apr 2009
Location: Douglasville, GA
Posts: 1,180
Default

anymore feedback?...
__________________
On Deck
perhaps a line of single hop IPA's - there's so many new hops out there!!!
Grizzlybrew is offline Reply With Quote
Old 02-05-2012, 02:40 AM   #5
Member
Recipes 
 
Join Date: Mar 2011
Location: Wilmington, NC
Posts: 36
Default

Quote:
Originally Posted by weirdboy View Post
Seems like that should work OK. I had one much lower rated, like maybe 200 GPH max, that I used in a 25' chiller that had about a 2 foot head height. That is really the key factor. What will be the height between the pump and the top of the chiller?

I assume you are using this to pump ice water?
Once the flow has traveled through the entire chiller, the key is not the difference in height between pump and chiller, rather the difference between flow beginning (pump inlet) and flow exit (chiller outlet). Changes in elevation between those points (ie having the chiller above the pump) will only affect starting the flow. During steady operation, you are siphoning within the chiller.

You can gain a few feet of head if you can have the flow start from a high elevation and drain to a lower one. It ain't pretty but that's how I squeeze some extra effort out of a small pump and narrow diameter tubing.
mdboulier is offline Reply With Quote
Old 02-05-2012, 02:51 AM   #6
Thistledown Brewery
 
runningweird's Avatar
Recipes 
 
Join Date: Dec 2009
Location: Greencastle, Pennsylvania
Posts: 1,481
Default

after the liquid has completed the loop suction will take over and it will matter less about head height.

I use a pond pump from lowes - it cost 29 dollars - to pump sub freezing salt water up 7 feet and back down - great flow rate.
__________________
My 6 Tap Long Draw Tower Build:
http://www.homebrewtalk.com/f35/long-draw-salt-water-chilled-beer-tower-271578/
runningweird is online now Reply With Quote
Old 02-05-2012, 03:18 PM   #7
Senior Member
 
Grizzlybrew's Avatar
Recipes 
 
Join Date: Apr 2009
Location: Douglasville, GA
Posts: 1,180
Default

Quote:
Originally Posted by mdboulier View Post
Changes in elevation between those points (ie having the chiller above the pump) will only affect starting the flow. During steady operation, you are siphoning within the chiller.
Quote:
Originally Posted by runningweird View Post
after the liquid has completed the loop suction will take over and it will matter less about head height.

I use a pond pump from lowes - it cost 29 dollars - to pump sub freezing salt water up 7 feet and back down - great flow rate.
Good point I had not thought about. BTW, the pump worked great. In fact, almost too well. I tried to reduce the flow to grab more heat and didn't see much response. I'll play around with it more later. I did a quick experiment yesterday and had a pretty good overall chilling experience. I did run out of ice at the end and had to estimate the true, final chilling period of the wort.



__________________
On Deck
perhaps a line of single hop IPA's - there's so many new hops out there!!!
Grizzlybrew is offline Reply With Quote
Reply
Thread Tools
Display Modes


Similar Threads
Thread Thread Starter Forum Replies Last Post
Water Pump for Immersion Chiller Stankonia Equipment/Sanitation 1 04-30-2011 08:13 PM
2 Stage Immersion Chiller with Pump ? cheffriz Equipment/Sanitation 24 04-05-2011 11:46 PM
Immersion chiller pump xxdcmast Equipment/Sanitation 14 06-07-2009 01:38 AM
Aquarium pump requirements for 25'x3/8" Immersion Chiller reshp1 Equipment/Sanitation 10 04-21-2008 10:21 PM





Contact Us - Top - Privacy - All times are GMT. The time now is 08:19 PM.
Copyright © Group Builder, Inc - All Rights Reserved
Craft Beer & Brewery Forum