|
View Poll Results: Weldless bulkheads and leakage
|
|
I've used weldless fittings on my boil vessel, never had a leak
|
  
|
14 |
31.11% |
|
I've used weldless fittings, had a leak, fixed it and I'm good
|
  
|
10 |
22.22% |
|
I tried weldless fittings, got a leak, couldn't get it resolved
|
  
|
2 |
4.44% |
|
I've got weldless fittings, have a small leak, but I deal
|
  
|
5 |
11.11% |
|
I hate the very idea of weldless fittings, but I still want to vote, dammit!
|
  
|
1 |
2.22% |
|
Ralph Nader
|
  
|
13 |
28.89% |
 |
10-27-2008, 04:43 PM
|
#1
|
|
10th-Level Beer Nerd
Feedback Score: 0 reviews
Join Date: May 2006
Location: Adams, MA
Posts: 19,850
Liked 239 Times on 190 Posts Likes Given: 53
|
Weldless fittings and leakage
|
|
Some people love 'em, some people hate 'em....
If you've used weldless fittings on your boil kettle, have they leaked on you?
If they have, did you ever figure out why (didn't clean the burr on the drill hole and screwed up the o-ring, etc)?
__________________
Come join Yankee Ingenuity!
"I'm kind of toasted. But I looked at my watch and it's only 6:30 so I can't stop drinking yet." - Yooper's Bob
"Brown eye finally recovered after the abuse it endured in Ptown last weekend, but it took almost a full week." - Paulie
"no, he just doesn't speak 'stupid'. i, however, am fluent...." - motobrewer
|
|
|
10-27-2008, 04:49 PM
|
#2
|
|
Feedback Score: 0 reviews
Join Date: Dec 2007
Location: Oconomowoc, Wisconsin
Posts: 8,458
Liked 94 Times on 84 Posts Likes Given: 11
|
I would much prefer welded fittings, but my weldless are fine for now. I've had to fix a few leaks, but overall they are fine.
I really wanted to vote for Nader.
|
|
|
10-27-2008, 04:51 PM
|
#3
|
|
Kwanesum Chinook Illahee
Feedback Score: 0 reviews
Join Date: Oct 2007
Location: Portland, OR
Posts: 3,267
Liked 11 Times on 10 Posts Likes Given: 1
|
I've got weldless on my boil kettle and my HLT. Boil kettle they are fine. No leaks. HLT I have minor leaks, but I believe that was due to placement. I have them too close to the bumps on the keg and I can't get them flat.
|
|
|
10-27-2008, 04:51 PM
|
#4
|
|
Feedback Score: 0 reviews
Join Date: Apr 2008
Location: Columbia, SC
Posts: 331
|
1 for Nader...maybe he can win this election
__________________
"Good people drink good beer." -Hunter S. Thompson
Apfelwein and beer...
|
|
|
10-28-2008, 12:15 PM
|
#5
|
|
Hobby Collector
Feedback Score: 0 reviews
Join Date: Nov 2007
Location: Southern Ohio
Posts: 36,844
Liked 1965 Times on 1945 Posts Likes Given: 67
|
I voted
"I've used weldless fittings, had a leak, fixed it and I'm good"
But that one leak was in the middle of a boil causing severe annoyance. I have since went welded. It's likely you won't get a leak if installed properly, but the $25 per keg I paid was well worth the piece of mind.
__________________
Tap Room Hobo
I should have stuck to four fingers in Vegas. :o - marubozo
|
|
|
10-28-2008, 12:28 PM
|
#6
|
|
Feedback Score: 0 reviews
Join Date: Jun 2007
Location: Delaware
Posts: 3,278
Liked 21 Times on 19 Posts
|
I have 3 keggles with 6 weldless fittings and the only one to even remotely leak is one of the Thermosights. I had a hell of a time getting them to seal because of the stainless nipples. I had to add 2-3 SS washers on each side of the keg wall to get it to seal (after buying replacement nipples). The only leak is from my HLT and it's a slow drip, so overall I'm content with it.
I'd say for ball valves, weldless was the easiest and most cost effective, but it's a toss-up for the thermomter/sight gauge.
__________________
END TRANSMISSION
|
|
|
| Thread Tools |
|
|
| Display Modes |
Linear Mode
|
|
|
|