10-01-2010, 01:55 PM
|
#1
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2009
Location: Macungie, Pa
Posts: 1,540
Liked 94 Times on 60 Posts Likes Given: 35
|
Ranco not switching on or off.
|
|
Tested my brutus 20 last night and it seems that the Ranco is not switching correctly. Atleast not that I can tell. Shouldn't you be able to hear the relay click when it turns the element on and off? When I look into the HLT looks like the Heatstick is still heating the water even after it is supposed to be turned off. I have my first brew on it tomorrow and want to make sure everything is working correctly.
|
|
|
10-01-2010, 02:00 PM
|
#2
|
|
In yo' garage, steelin' yo parts.
Feedback Score: 0 reviews
Join Date: Jan 2008
Location: Oblivion
Posts: 44,168
Liked 3934 Times on 3769 Posts Likes Given: 47
|
Mine clicks.
You should also see the "S1" indicator on the display come on when it's on and go off when it's off.
|
|
|
10-01-2010, 02:03 PM
|
#3
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2009
Location: Macungie, Pa
Posts: 1,540
Liked 94 Times on 60 Posts Likes Given: 35
|
Yes I see the indicator but does not click at all. Not even when I switch between heating and cooling mode... Not sure what happend. It turns on and I get a display with no errors so I don't think it's wired wrong.
Do I want the wire in Normally open, or normally closed? That might be my problem. I have it in normally open.
|
|
|
10-01-2010, 02:06 PM
|
#4
|
|
Hobby Collector
Feedback Score: 0 reviews
Join Date: Nov 2007
Location: Southern Ohio
Posts: 37,245
Liked 2205 Times on 2177 Posts Likes Given: 79
|
The element will still be hot and you'll still see bubbles for a while. There should be an indicator on the display saying if the relay is on or off.
__________________
Tap Room Hobo
I should have stuck to four fingers in Vegas. :o - marubozo
|
|
|
10-01-2010, 02:07 PM
|
#5
|
|
Hobby Collector
Feedback Score: 0 reviews
Join Date: Nov 2007
Location: Southern Ohio
Posts: 37,245
Liked 2205 Times on 2177 Posts Likes Given: 79
|
Put a ohm meter across the relay out put and look for a change when the indicator on the display turns on.
__________________
Tap Room Hobo
I should have stuck to four fingers in Vegas. :o - marubozo
|
|
|
10-01-2010, 02:48 PM
|
#6
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2009
Location: Macungie, Pa
Posts: 1,540
Liked 94 Times on 60 Posts Likes Given: 35
|
I'll have to do that tonight. It seems to hold the temp I tell it to so maybe its just the residual heat of the element. Just thought I should be hearing the relay click on and off.
|
|
|
10-02-2010, 04:20 PM
|
#7
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2009
Location: Macungie, Pa
Posts: 1,540
Liked 94 Times on 60 Posts Likes Given: 35
|
looks like it's not switching off. Just stays on no matter what..
|
|
|
10-02-2010, 04:26 PM
|
#8
|
|
Feedback Score: 0 reviews
Join Date: Dec 2007
Posts: 9,100
Liked 145 Times on 139 Posts Likes Given: 4
|
Quote:
Originally Posted by CoalCracker
looks like it's not switching off. Just stays on no matter what..
|
Did you wire it?
|
|
|
10-02-2010, 04:47 PM
|
#9
|
|
Senior Member
Feedback Score: 0 reviews
Join Date: Sep 2009
Location: Macungie, Pa
Posts: 1,540
Liked 94 Times on 60 Posts Likes Given: 35
|
yes
|
|
|
10-02-2010, 05:44 PM
|
#10
|
|
Feedback Score: 0 reviews
Join Date: Dec 2007
Posts: 9,100
Liked 145 Times on 139 Posts Likes Given: 4
|
Quote:
Originally Posted by CoalCracker
yes
|
Did you double and triple check it? It's not hard to cross a wire in there.
|
|
|
| Thread Tools |
|
|
| Display Modes |
Linear Mode
|
|
|
|