Default pid tempurature counting down??

so i bought 2 new K thermocouples for my pids.. whn they heat up they count down instead of up.. now i wired the red wires to positive and the whites to negative on the pid inputs... now my question is should i revers the wires to get them to read normal as in (heat up the readout goes up not down)?

__________________
kickflip_mj is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 04:16 AM   #2
CodeRage
Death by Magumba!
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
CodeRage's Avatar
Recipes 
 
Join Date: Aug 2007
Location: Melbourne, Fl
Posts: 2,254
Liked 29 Times on 16 Posts
Likes Given: 5

Default

yes, you have the leads backwards.

__________________
Brutus 20e build | Electrical Primer for Brewers | Auber SYL-2362A2 PID Install & Config
So as I am walking out the door this morning I think to my self:
"self, going to work on Monday is like knowing you're going to get kicked in the nuts. You just don't know when or by who"
CodeRage is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 04:45 AM   #3
kickflip_mj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2008
Posts: 854
Liked 83 Times on 53 Posts
Likes Given: 3

Default

see thats what i thought.. so is the red wire hot? its just odd hw they were labeled. you should have seen me in my garage, i wanted to yell "what now god!!!"

__________________
kickflip_mj is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 05:42 AM   #4
ClaudiusB
Feedback Score: 0 reviews
Recipes 
 
Join Date: Dec 2007
Location: El Paso, Texas
Posts: 1,262
Liked 57 Times on 49 Posts
Likes Given: 110

Default

Quote:
so i bought 2 new K thermocouples for my pids.. whn they heat up they count down instead of up.. now i wired the red wires to positive and the whites to negative on the pid inputs...
Color code info.
ANSI color code for K type is RED and Yellow, J type is RED and White.


Cheers,
ClaudiusB
ClaudiusB is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 06:17 AM   #5
kickflip_mj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2008
Posts: 854
Liked 83 Times on 53 Posts
Likes Given: 3

Default

so not to repeat but just switch them and i should be good?

__________________
kickflip_mj is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 11:11 AM   #6
Sawdustguy
Feedback Score: 1 reviews
Recipes 
 
Join Date: Mar 2009
Location: Manorville, New York
Posts: 2,761
Liked 28 Times on 25 Posts

Default

Quote:
Originally Posted by kickflip_mj View Post
so not to repeat but just switch them and i should be good?

Thats a 10-4 there.
__________________

Guy

Brewery URL: Black Dog Brewery NY

BBQ Team URL: Two Fat Polocks BBQ Team

Sawdustguy is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 02:36 PM   #7
kickflip_mj
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2008
Posts: 854
Liked 83 Times on 53 Posts
Likes Given: 3

Default

thanks once again guys, i really appreciate it.

Sawdust guy,

i wired my pid exactly how you drew it up a couple of weeks ago with the wall wort between the ssr and the pid and it works great except for my temp counting down. thank you

__________________
kickflip_mj is offline
 
Reply With Quote Quick reply to this message
Old 08-04-2009, 02:42 PM   #8
jkarp
Beer Herder
HBT_SUPPORTER.png
Feedback Score: 0 reviews
 
jkarp's Avatar
Recipes 
 
Join Date: Jun 2008
Location: Elizabeth, CO
Posts: 2,105
Liked 33 Times on 29 Posts
Likes Given: 4

Default

Thermocouple color codes vary by country too so don't trust squat. US made K types have a negative red, but the ones Auber sells are imported so the red is positive. If one of the leads on your thermocouple is ferrous (K types are), it's easy enough to identify the negative lead with a magnet.

__________________
jkarp is offline
 
Reply With Quote Quick reply to this message
Old 08-05-2009, 09:41 AM   #9
Sawdustguy
Feedback Score: 1 reviews
Recipes 
 
Join Date: Mar 2009
Location: Manorville, New York
Posts: 2,761
Liked 28 Times on 25 Posts

Default

Quote:
Originally Posted by kickflip_mj View Post
thanks once again guys, i really appreciate it.

Sawdust guy,

i wired my pid exactly how you drew it up a couple of weeks ago with the wall wort between the ssr and the pid and it works great except for my temp counting down. thank you
I am happy I could help. Keep up the good work.
__________________

Guy

Brewery URL: Black Dog Brewery NY

BBQ Team URL: Two Fat Polocks BBQ Team

Sawdustguy is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
tempurature control on fridge blackwaterbrewer DIY Projects 4 05-20-2009 09:41 PM
What tempurature information to track? Hanr3 Beginners Beer Brewing Forum 3 11-19-2008 07:19 AM
Fridge/Freezer Tempurature Difference DublOh7 Equipment/Sanitation 4 11-09-2006 10:13 PM
400 and counting...... Beermaker General Chit Chat 16 03-04-2006 12:35 AM
Secondary Tempurature Igorstien Beginners Beer Brewing Forum 10 09-04-2005 07:13 PM



Newest Threads