Default HERMS copper pipe size

Thinking of eventually building a herms system.

IT seems most people go for 1/2 inch copper tubing, that I have seen. Is there a benefit to this? 3/8 is a fair bit cheaper, and wouldn't it have more surface area to dissapate heat?

__________________

.
It's just beer man.... they've been doing it for years......

CanadianNorth is offline
 
Reply With Quote Quick reply to this message
Old 04-06-2011, 06:06 PM   #2
benbradford
Feedback Score: 3 reviews
Recipes 
 
Join Date: May 2007
Location: Denver, Colorado
Posts: 954
Liked 27 Times on 24 Posts

Default

3/8 has less surface area...water would spend less time in coil also...it is all about efficiency, if you want things to happen faster, go with 1/2, if you want to spend less money, go with 3/8. I went with 25 feet of 3/8, and then when money was available to put into the hobby, I added another 25 feet with a compression fitting connector.

__________________

I think it's too bad that everybody's decided to turn on drugs, I don't think drugs are the problem. Crime is the problem. Cops are the problem. Money's the problem. But drugs are just drugs.
Jerry Garcia

benbradford is offline
 
Reply With Quote Quick reply to this message
Old 04-06-2011, 07:26 PM   #3
CanadianNorth
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2009
Location: Newfoundland, Canada
Posts: 110
Default

Ok. I currently use 3/8 for my chiller, 50 feet with a connector. I will look at the price difference and decide.

__________________

.
It's just beer man.... they've been doing it for years......

CanadianNorth is offline
 
Reply With Quote Quick reply to this message
Old 04-06-2011, 07:31 PM   #4
Ohio-Ed
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
Ohio-Ed's Avatar
Recipes 
 
Join Date: Nov 2008
Posts: 2,072
Liked 19 Times on 18 Posts

Default

Quote:
Originally Posted by CanadianNorth View Post
Thinking of eventually building a herms system.

IT seems most people go for 1/2 inch copper tubing, that I have seen. Is there a benefit to this? 3/8 is a fair bit cheaper, and wouldn't it have more surface area to dissapate heat?
With a HERMs coil, you are at the mercy of your pumps capacity. 3/8" copper will have more resistance and you will have significantly less flow which may or may not be a problem.

3/8" is fine for an IC because typically you use residential water pressure.

Ed
__________________
Ohio-Ed is offline
 
Reply With Quote Quick reply to this message
Old 04-07-2011, 12:24 AM   #5
CanadianNorth
Feedback Score: 0 reviews
Recipes 
 
Join Date: Aug 2009
Location: Newfoundland, Canada
Posts: 110
Default

Quote:
Originally Posted by Ohio-Ed View Post
With a HERMs coil, you are at the mercy of your pumps capacity. 3/8" copper will have more resistance and you will have significantly less flow which may or may not be a problem.

3/8" is fine for an IC because typically you use residential water pressure.

Ed
Good point. I hadn't thought of it that way......
__________________

.
It's just beer man.... they've been doing it for years......

CanadianNorth is offline
 
Reply With Quote Quick reply to this message
Old 04-07-2011, 04:28 AM   #6
EarthBound
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2010
Location: Beer Capital of the World
Posts: 984
Liked 10 Times on 9 Posts
Likes Given: 84

Default

Just to clarify things up for the many people that read this, please specify OD or ID when you say 1/2" or 3/8", please thank you.

__________________

"You can do anything you set your mind to when you have vision, determination, and an endless supply of beer."

EarthBound is offline
 
Reply With Quote Quick reply to this message
Old 04-07-2011, 04:30 AM   #7
o4_srt
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jan 2010
Location: Lancaster, PA
Posts: 1,330
Liked 14 Times on 14 Posts

Default

Quote:
Originally Posted by EarthBound
Just to clarify things up for the many people that read this, please specify OD or ID when you say 1/2" or 3/8", please thank you.
1/2" is id for rigid copper pipe, 3/8" is od for copper tubing. A 3/8" to 1/2" rigid adapter will not join the two, found out the hard way yesterday. You need a 3/8" compression to 1/2" slip fitting to accomplish this.
__________________
Facebite Brewing

Conditioning: Muddy Paw Nut Brown Ale, Jump The Fence Independence Cream Ale
o4_srt is offline
 
Reply With Quote Quick reply to this message
Old 04-07-2011, 03:26 PM   #8
rcrabb22
HBT_LIFETIMESUPPORTER.png
Feedback Score: 0 reviews
 
rcrabb22's Avatar
Recipes 
 
Join Date: Jun 2008
Location: Illinois
Posts: 734
Liked 21 Times on 15 Posts
Likes Given: 17

Default

Quote:
Originally Posted by Ohio-Ed View Post
With a HERMs coil, you are at the mercy of your pumps capacity. 3/8" copper will have more resistance and you will have significantly less flow which may or may not be a problem.

3/8" is fine for an IC because typically you use residential water pressure.

Ed
I currently have 1/2" OD copper HERMs and I have to restrict the flow to such a degree that I think 3/8" would have been a viable option.
__________________
rcrabb22 is offline
hot_carl Likes This 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools


Similar Threads
Thread Thread Starter Forum Replies Last Post
cleaning copper pipe red123 Equipment/Sanitation 9 01-28-2012 09:32 PM
Best Place to Buy Copper Pipe? stjackson Equipment/Sanitation 7 02-15-2011 12:33 PM
Chemicals on copper pipe? Dgonza9 Equipment/Sanitation 11 02-08-2011 12:24 PM
Questions about copper poisoning/copper pipes + hoses in herms system kingoslo Equipment/Sanitation 32 08-24-2010 12:43 AM
Cleaning copper pipe 2nd Street Brewery Equipment/Sanitation 6 09-25-2006 09:57 PM