Default Brew day White Labs screwup

Sort of crappy brew day today. Making a dark IPA - first of all couldn't get a good boil outside on a windy cool Chicago afternoon. Just weakly roiling without a hot break for over an hour. Eventually brought it inside, started a real boil on the stove, hopped appropriately, cooled, etc, etc. Went to pitch the White Labs yeast and (stupidly) opened it right over the bucket. Of course, it sprayed all over the place, dripped down my hands and the vial and into the fermenter. Anyone else ever done this? What do you think my chances of a non-infected batch are? I was just looking at a stirrer at the LHBS literally yesterday thinking I should be making starters, but here we are. After all that almost-boiling, it ended up with an OG of 1.080, if that matters at all. I know you're going to say just finish it and see if it works, but I was wondering if anyone else had done this.



__________________
SuperNintendoChalmers is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 02:08 AM   #2
E-Mursed
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Westland, MI
Posts: 893
Liked 105 Times on 65 Posts
Likes Given: 10

Default

Not personally....but this is where great brewing stories come from.

You have 3 - 4 weeks of patience to learn. Trust in your process and you just might be alright.



__________________
Schöne Blondine Brauerei
Closed-System Pressurized Fermentation - the future of homebrewing today...!!!

“Simplicity is the ultimate sophistication” – Leonardo da Vinci
"A set back is the opportunity to begin again more intelligently" - Henry Ford
E-Mursed is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 02:30 AM   #3
Euphist
Feedback Score: 0 reviews
 
Euphist's Avatar
Recipes 
 
Join Date: Jan 2012
Location: Jacksonburg, WV
Posts: 490
Liked 44 Times on 34 Posts
Likes Given: 32

Default

I always dunk my hands and the whole vial in sanitizer before opening.

__________________
Euphist is online now
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 02:41 AM   #4
chumpsteak
Feedback Score: 0 reviews
Recipes 
 
Join Date: May 2011
Location: Meridian, ID
Posts: 842
Liked 92 Times on 78 Posts
Likes Given: 10

Default

I'd be more worried about pitching only 1 vial of yeast in a 1.080 OG batch. Mr.Malty recommends 3 vials for that OG.

__________________
chumpsteak is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 09:10 AM   #5
photogscott
Feedback Score: 0 reviews
Recipes 
 
Join Date: Mar 2007
Location: Long Beach CA
Posts: 186
Liked 3 Times on 3 Posts

Default

Yeah ive gotten yeast on the fingers with no problem. 1 vial for a 1.080 isn't the recommended amount, but if you aererate the hell out of your wort it should work. Believe me Ive done 1.080 wort a few times with one vial and no starter.

__________________
photogscott is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 12:24 PM   #6
b-boy
Senior Member
Feedback Score: 0 reviews
 
b-boy's Avatar
Recipes 
 
Join Date: Jun 2011
Location: GETZVILLE, NY
Posts: 2,153
Liked 345 Times on 258 Posts
Likes Given: 99

Default

The White Labs vials always blow up like that. Kinda like a can of coke that got shaken.

I dunk them in Star San along with my hands and open them very slowly. I just crack them enough to get them to hiss and reseal. I do that about 5 times to purge all the CO2. It takes a few minutes, but it's better than getting sprayed in the face.

__________________
b-boy is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 03:29 PM   #7
SuperNintendoChalmers
Feedback Score: 0 reviews
Recipes 
 
Join Date: Nov 2011
Location: Chicago, IL
Posts: 22
Liked 1 Times on 1 Posts

Default

Ugh. It's probably even more underpitched than just a single vial, since the vial didn't even empty all the way because it was so foamy. Is it worth re-pitching? It's fairly well aerated, but do you think it's worth opening it to do a better job? Dunking your hands is a good idea. I don't know why I didn't, given that I had an open 5 gallon bucket of StarSan within arms reach. Sigh, we'll see I guess. Relax and have a homebrew, right?

__________________
SuperNintendoChalmers is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 04:22 PM   #8
TopherM
Vinz Clortho - the Keymaster of Gozer the Gozerian
Feedback Score: 0 reviews
 
TopherM's Avatar
Recipes 
 
Join Date: Mar 2011
Location: St. Petersburg, FL
Posts: 3,586
Liked 349 Times on 279 Posts
Likes Given: 18

Default

Skinner!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

__________________

Primary #1 - Cherry Wood Smoked Cranberry Cider
Primary #2 - Smoked Vidalia Onion Beer
Primary #3 - Schwartzbier
Secondary #1 - Downtown Flanders Brown
Keg #1 - EMPTY!
Keg #2 - EMPTY!
Keg #3 - EMPTY!
Bottled - NONE!

TopherM is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 10:59 PM   #9
ne0t0ky0
Feedback Score: 0 reviews
Recipes 
 
Join Date: Jul 2010
Location: Pflugerville, Texas
Posts: 313
Liked 9 Times on 9 Posts
Likes Given: 7

Default

I *hate* the white lab tubes for this very reason. If I don't shake it, then I leave yeast behind, if I shake then it's a foamy mess. Unless I *have* to have the WLP yeast I use wyeast activator; self proofing and easy to pour.

BTW, my very first homebrew had this issue and it turned out fine; ie no infection.

__________________
Blog Recipes
ne0t0ky0 is offline
 
Reply With Quote Quick reply to this message
Old 02-27-2012, 11:31 PM   #10
mulhaircorey
Feedback Score: 0 reviews
Recipes 
 
Join Date: Feb 2012
Location: Davis, California
Posts: 29
Default

You'll be fine.

Next time, crack the WL yeast vials while they are cold, just enough to allow the condensed CO2 to escape. Put the vial in a sterile beaker or glass standing up and allow it to come to room temp (while you're brewing, as usual) and occasionally re-crack as the brew goes on to allow any more CO2 to be released. If you can't get all the yeast out of the vial upon pitch, add some room temperature boiled and clean water to the vial, not all the way, and mix up the slurry, then pitch the rest!



__________________
mulhaircorey is offline
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options
Thread Tools
Display Modes


Similar Threads
Thread Thread Starter Forum Replies Last Post
White Labs Vial Label Removal Blender Equipment/Sanitation 29 04-27-2013 01:52 AM
White Rust dogtailale Equipment/Sanitation 2 11-02-2010 11:41 PM
B Brite screwup? HOT Water rinsing question? leoglenwood Equipment/Sanitation 2 08-27-2008 10:58 PM
White Floaties in an old brew Torchiest Equipment/Sanitation 8 03-14-2008 08:57 PM
White Vinegar sanitation flyboy Equipment/Sanitation 14 10-16-2007 01:10 PM